Skip to content

RadonAway

RadonAway Checkpoint IIA

Radon system fan alarm

  • System indicator
  • Fan alarm
  • Tubing

Best for, and skip if

Best for you if

  • Your system has a U-tube gauge and no alarm, and you want the active monitor Minnesota requires beside it.
  • The fan and its pipe are somewhere you rarely go, such as a garage, an attic or a crawlspace, and you want to hear when the suction drops.

Skip it if

  • There is no outlet near the pipe; RadonAway's page lists a transformer and power cord and names no battery.
  • The alarm would be out of earshot where the pipe runs; RadonAway's remote model, the 28001-4, carries the alarm to another room on 50 feet of wire.
  • RadonAway Checkpoint IIA

Photos: RadonAway

  • Made ofFan alarm
  • PackageTubing
  • Every figure checked against the specifications RadonAway publishes
  • The maker's own figures and limits, shown the same way for every part, unranked
Compare with similar items

About this item

As RadonAway states it

  • What it reads: Vacuum in the radon system's pipe, through tubing; factory preset to activate at .25" WC vacuum pressure; does not measure radon
  • Made of: Fan alarm: audible alarm with a green and red LED light readout
  • Package: Tubing (24' in the page's description, 24" in its feature list), 6' power cord, screws and an AC to DC low voltage transformer

The Checkpoint IIA is RadonAway's plug-in alarm for a radon mitigation system: it connects to the system's pipe with tubing, has an audible alarm and green and red LED lights, and is factory preset to activate at .25 inches of water column of vacuum. RadonAway's fan manual names it as one of the system monitors a radon system needs. Like any fan alarm, it reports on the fan and the pipe, not on how much radon is in the home.

What you get

RadonAway lists the Checkpoint IIA's features as an audible alarm, a green and red LED light readout, an included AC to DC low voltage transformer, and tubing, a 6 foot power cord and screws. The remote model's page lists the same and adds the remote alarm feature with 50 feet of wire.

In the box and running costs

How it works

What it does and how

What it is made of and the job it does in a system, then who has checked it

How it works

In our words, from the maker's documents

RadonAway describes the Checkpoint IIA in a few lines: it has an audible alarm and easy to read green and red LED lights, and it is factory preset to activate at .25" WC vacuum pressure. It comes with tubing, a 6 foot power cord and screws, and an AC to DC low voltage transformer, so it runs from a wall outlet rather than a battery. The tubing is what connects it to the radon pipe, where the fan's suction is.

That makes it the active half of a pair. Minnesota's health department requires every radon mitigation system to have two fan monitors, a U-tube manometer and an active notification monitor, and describes what the second one does: it alerts you with a visual light and/or audible noise if the radon mitigation system stops working. A U-tube has to be looked at to be read; an alarm like this one makes itself heard.

RadonAway's RP Series fan instructions put the alarm in the same place as a gauge. Under System Monitor and Label they say a system monitor, such as a manometer (P/N 50017) or an audible alarm (P/N 28001-2), is required to notify the occupants of a fan system malfunction. The 28001-2 is this alarm. RadonAway also makes a remote version, the Checkpoint IIAR (P/N 28001-4), which can be wired to a remote location where it is most likely to be heard, with 50 feet of wire included.

What the alarm cannot do is the point most worth keeping. It reports on suction, so a quiet alarm says the fan is pulling, not that the radon level is low. Minnesota says the same of a U-tube gauge: it does not show or measure radon levels, it shows there is suction in the pipe. Only a radon test shows the level in the home.

What the manufacturer says

RadonAway's own statements, attributed

  • RadonAway saysRadonAway states the Checkpoint IIA has an audible alarm and easy to read green and red LED lights.
  • RadonAway saysRadonAway states the alarm is factory preset to activate at .25" WC vacuum pressure.
  • RadonAway saysRadonAway lists an AC to DC low voltage transformer as included.
  • RadonAway saysRadonAway says the Checkpoint IIA Mitigation System Alarm also comes in a Remote Alarm model (P/N 28001-4).
  • RadonAway saysRadonAway says the remote model can be wired to a remote location where it is most likely to be heard, with 50' of wire included.

These are RadonAway's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.

Independent evidence

Who checks a device like this

C-NRPP's consumer evaluation covers electronic radon monitors, not the parts of a mitigation system, so it has no result for RadonAway Checkpoint IIA. The standards and results the maker states are under “What the manufacturer says”, and what shows whether radon in your home is lower is a radon test after the work is done.

Specifications

Specifications

Every figure as the maker states it

Compare side by side

The maker's figures

Type
System indicator, Plug-in radon system fan alarm
What it reads
Vacuum in the radon system's pipe, through tubing; factory preset to activate at .25" WC vacuum pressure; does not measure radon
Range
Not stated by the manufacturer
Made of
Fan alarm: audible alarm with a green and red LED light readout
Package
Tubing (24' in the page's description, 24" in its feature list), 6' power cord, screws and an AC to DC low voltage transformer
Warranty
Not stated by the manufacturer

What is in the box

RadonAway lists the Checkpoint IIA's features as an audible alarm, a green and red LED light readout, an included AC to DC low voltage transformer, and tubing, a 6 foot power cord and screws. The remote model's page lists the same and adds the remote alarm feature with 50 feet of wire.

Neither page states a warranty for the alarm; the trade store's five-year line is about RadonAway's fans. RadonAway notes that the Checkpoint IIA is also available through its Canadian distribution location.

What it costs to run

The alarm runs from a wall outlet through its transformer; RadonAway states no power draw for it, and names no battery to replace. What it asks for is a working outlet and a monthly look: Minnesota asks that the active monitor's power source be checked monthly. The fan it watches runs all the time: the EPA says the fan should never be turned off and that fans may last for five years or more.

The ongoing cost is testing. The EPA says it is a good idea to retest your home at least every two years, and RadonAway's fan instructions say the system label must tell the occupants that regular radon tests are needed. An alarm that stays quiet does not replace those tests.

Fit and setup

Who it fits, and installation

The fit, then how it goes on and what the standards ask

Who it fits

Good fit if, and look elsewhere if

Good fit if

  • Your system has a U-tube gauge and no alarm, and you want the active monitor Minnesota requires beside it.
  • The fan and its pipe are somewhere you rarely go, such as a garage, an attic or a crawlspace, and you want to hear when the suction drops.
  • You have a RadonAway RP fan and want the audible alarm its instructions name by part number.
  • There is a wall outlet near the pipe, since RadonAway powers it with an included transformer and power cord.

Look elsewhere if

  • There is no outlet near the pipe; RadonAway's page lists a transformer and power cord and names no battery.
  • The alarm would be out of earshot where the pipe runs; RadonAway's remote model, the 28001-4, carries the alarm to another room on 50 feet of wire.
  • You want to choose the trip point; RadonAway's page gives one factory preset, .25" WC, and names no other setting.
  • You want to know your radon level; the alarm reports on the fan's suction, and only a radon test shows radon.

Installation

3 steps

  1. RadonAway links a Checkpoint installation sheet from the product page, and its retail page says that installing a radon fan or system yourself is not intended to take the place of installation by a qualified radon professional. The product page's own contents list is the tubing, a 6 foot power cord, screws and the transformer. It gives the tubing as 24 feet in its description and 24 inches in its feature list, so check what is in the box against the installation sheet before you plan where the alarm goes.
  2. Where it goes matters as much as how. The EPA's 1994 Radon Mitigation Standards say every active system needs a mechanism to monitor system performance and warn of failure, simple to read and placed where occupants can easily see or hear it. The EPA's consumer guide says the warning device must be placed where it can be seen or heard easily, lists a sound alarm and a light indicator among the examples, and recommends a qualified radon mitigation contractor for the system itself.
  3. RadonAway's fan instructions ask the installer to verify the system vacuum with a manometer and to keep it within the normal operating range and below the fan's maximum recommended operating pressure. Minnesota adds two checks that apply to an alarm in particular: the active monitor's power source should be checked monthly, since it could be plugged in or use batteries, and both fan monitors should be checked monthly to make sure the system is working.

For how the sealing, the gauge and the fan work together, see radon mitigation systems, and to find someone to design and install one, radon mitigation professionals.

Compare

Compare with similar items

The same three rows for each, and the one difference that matters

Compare side by side
  • This page

    RadonAway Checkpoint IIA

    What it is
    Fan alarm
    Power
    Not stated
    C-NRPP 2024/25
    Not applicable (system part)

    This page: The Checkpoint IIA is RadonAway's plug-in alarm for a radon mitigation system: it connects to the system's pipe with tubing, has an audible alarm and green and red LED lights, and is factory preset to activate at .25 inches of water column of vacuum.

  • What it is
    Passive U-tube manometer
    Power
    Not stated
    C-NRPP 2024/25
    Not applicable (system part)

    The difference: AprilAire's U-tube gauge, which AprilAire pitches as a secondary indicator that vacuum pressure has changed when a system alarm goes off.

  • What it is
    Moves up to 375 CFM
    Power
    Up to 139 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: A whole kit with its own alarm: AprilAire says the ARN25K includes the ARN25F fan, an ARNALM alarm, an ARN05M manometer and coupling(s).

  • What it is
    U-tube manometer with non-toxic fluid, adjustable zero and a molded scale curved to fit the system pipe
    Power
    Not stated
    C-NRPP 2024/25
    Not applicable (system part)

    The difference: RadonAway's U-tube gauge for the same pipe, which has to be read rather than heard: it reads 0 to 4.5" WC with non-toxic fluid and an adjustable zero.

Questions

Questions people ask

5 questions about the RadonAway Checkpoint IIA, answered

Asked about the Checkpoint IIA

Does the Checkpoint IIA detect radon?

No. It senses the suction in the radon pipe, which tells you whether the fan is pulling, not how much radon is in the home. Only a radon test shows the level, and the EPA says it is a good idea to retest at least every two years.

When does it sound?

RadonAway says it is factory preset to activate at .25" WC vacuum pressure, with an audible alarm and green and red LED lights. Minnesota's description of any active monitor is that it alerts you with a light and/or noise if the radon mitigation system stops working.

Do I still need a U-tube gauge?

Minnesota requires both: every radon mitigation system needs a U-tube manometer and an active notification monitor. RadonAway's fan manual names either a manometer or an audible alarm as the required system monitor, and the EPA's 1994 standards ask that a manometer be marked with the range of readings the system had when it was first activated.

What is the Checkpoint IIAR?

RadonAway's remote model, P/N 28001-4. Its page says it can be wired to a remote location where it is most likely to be heard, with 50 feet of wire included, and lists the same LED lights, audible alarm, transformer and .25" WC preset.

What should I check if it goes off?

Minnesota's checks for a system that seems to have stopped: make sure the monitor tubing is connected to the pipe and not kinked, and that power is being supplied to the fan. In cold weather it also warns of system freeze-up, when ice in the pipe stops radon venting properly; then the U-tube fluid will be even and the active monitor should alert you. For the system itself, the EPA recommends a qualified radon mitigation contractor.

Updated November 27, 2026