Skip to content

Festa

Festa AMG Hawk EC

EC inline radon fan

  • Radon fan
  • 6 in. flexible couplers

Best for, and skip if

Best for you if

  • Your home or building covers 2,000 to 3,500 square feet over gravel or another porous fill, the range Festa gives the Hawk EC.
  • You want more air at 1 inch of suction than the AC Hawk offers: Festa's RRNC page lists 175 CFM for the EC against 130 for the AC fan.

Skip it if

  • You want to dial the speed down; Festa sells that as the AMG Hawk ECS, and its EC instructions say not to add an external speed control.
  • You need Festa's full airflow curve, maximum pressure or wattage before choosing; the Festa pages and documents read for this page give only two airflow points.
  • Festa AMG Hawk EC

Photos: Festa

  • Pipe size6 in. flexible couplers (product page); Festa's installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
  • Every figure checked against the specifications Festa publishes
  • The maker's own performance table, point by point, unranked
Tests that check it works

About this item

As Festa states it

  • Motor: EC
  • Pipe size: 6 in. flexible couplers (product page); Festa's installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
  • Outdoor use: Rated for outdoor installation
  • Warranty: 7-year full-replacement warranty for EC fans from the date of original purchase, for customers who bought directly from Festa (Festa's warranty document); Festa's EC installation instructions print a seven year warranty from the date of manufacture and a clause offering five full years from manufacture

The AMG Hawk EC is the electronically commutated version of Festa's 6 inch Hawk, a white fan for 6 inch flexible couplers that Festa sells alone or with a 3 inch or 4 inch installation kit. Festa's RRNC page lists it at 235 CFM at 0.5 inch of water column and 175 CFM at 1.0 inch, and Festa recommends it for homes or structures of 2,000 to 3,500 square feet over porous sub-slabs such as gravel, with a 7-year warranty for its EC fans.

What you get

Festa's Hawk EC page lists three styles: fan only, 3 inch installation kit and 4 inch installation kit, in white. Each kit holds two white Fernco couplers that fit the fan to 3 inch or 4 inch PVC pipe, a green 5.5 inch radon system manometer, a line cord with connector and system labels. The fan-only style comes without couplers; Festa sells the 6 inch flexible couplers it fits separately.

In the box and running costs

How it works

What it does and how

The suction, the airflow and the housing, then who has checked it

How it works

In our words, from the maker's documents

Under the motor change, the job is the same as any radon fan's. The EPA's consumer guide describes the vent fan drawing radon from below the home through the suction pipes and venting it outside while it creates a negative pressure beneath the slab, and it says the fan must run continuously, never turned off.

An EC fan, short for electronically commutated, runs a brushless motor with its own electronics in place of the plain AC motor in fans like the original Hawk. Festa's EC collection page describes its EC fans as energy-efficient and brushless, and says the brushless design reduces wear, increasing longevity and minimizing maintenance needs. Those are Festa's descriptions; it gives no hours or efficiency figure for them.

Festa publishes two airflow points for the Hawk EC, both on its RRNC fan types page: 235 CFM at 0.5 inch of water column and 175 CFM at 1.0 inch. The same page lists the AC Hawk at 130 CFM at 1.0 inch, so by Festa's own table the EC version moves 45 CFM more at that pressure. For the AC fan, Festa's 2022 catalog lists 230 CFM at 0.5 inch, close to the EC's 235.

Those two points are all Festa has published on the Hawk EC's performance in the pages and documents read for this page: no maximum pressure, no free-air figure, no wattage. Its EC installation instructions say the supply must match the unit rating label, so the label on the fan is where the electrical figures will be, and Festa's phone line is the place to ask for a full curve before sizing a system around it.

On the RRNC page the Hawk EC sits between Festa's other EC fans for porous ground: the Maverick EC at 150 CFM at 0.5 inch and 117 at 1.0, and the Legend EC at 238 and 180. Festa's Hawk EC page says the fan offers more airflow than the Maverick EC and pitches it at the same 2,000 to 3,500 square feet it gives the AC Hawk, over porous sub-slabs such as gravel.

There is also a Hawk with a dial. Festa's AMG Hawk ECS page calls it the Hawk EC with an integral speed controller, a potentiometer inside the terminal box that sets the speed to what the system needs. The plain Hawk EC has no such control, and Festa's EC instructions say not to use an external speed control device on these fans.

Those EC instructions, whose model list names the Hawk EC, give it an ambient temperature range of -13°F (-25°C) to 140°F (60°C), and say the electric motor is protected by an internal overheat device. They also mark the fans for use with non-metallic conduit only.

What the manufacturer says

Festa's own statements, attributed

  • Festa saysFesta's RRNC page lists the AMG Hawk EC at 235 CFM at 0.5 inch and 175 CFM at 1.0 inch of water column.
  • Festa saysFesta says the AMG Hawk EC offers more airflow than the AMG Maverick EC.
  • Festa saysFesta states it recommends the AMG Hawk EC for homes or structures of 2,000 to 3,500 square feet with porous sub-slabs such as gravel.
  • Festa saysFesta gives the AMG Hawk EC an estimated noise range of 60 to 65 dB and says the figure can vary with the system configuration.
  • Festa saysFesta states its EC fans can be mounted indoors or outdoors and lists their ambient range for the Hawk EC as -13°F to 140°F.
  • Festa saysFesta's warranty document lists the AMG Hawk EC among its EC fans, which it states carry a 7-year full-replacement warranty.

These are Festa's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.

Independent evidence

Who checks a device like this

C-NRPP's consumer evaluation covers electronic radon monitors, not mitigation fans, so it has no result for Festa AMG Hawk EC. The safety listing and performance certification the maker states are under “What the manufacturer says”, and what shows whether any fan is working in your home is a radon test after it is installed.

Specifications

Specifications

Every figure as the maker states it

Compare side by side

The maker's figures

Type
Mitigation fan, inline
Motor
EC
Pipe size
6 in. flexible couplers (product page); Festa's installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
Max static pressure
Not stated by the manufacturer
Max airflow
Not stated by the manufacturer
Max power
Not stated by the manufacturer
Power supply
Not stated by the manufacturer
Speed control
Not stated by the manufacturer
Airflow at static pressure
Not stated by the manufacturer
Outdoor use
Rated for outdoor installation
Warranty
7-year full-replacement warranty for EC fans from the date of original purchase, for customers who bought directly from Festa (Festa's warranty document); Festa's EC installation instructions print a seven year warranty from the date of manufacture and a clause offering five full years from manufacture

What is in the box

Festa's Hawk EC page lists three styles: fan only, 3 inch installation kit and 4 inch installation kit, in white. Each kit holds two white Fernco couplers that fit the fan to 3 inch or 4 inch PVC pipe, a green 5.5 inch radon system manometer, a line cord with connector and system labels. The fan-only style comes without couplers; Festa sells the 6 inch flexible couplers it fits separately.

Festa's warranty paperwork gives the Hawk EC seven years, counted two ways. The warranty document lists it among the EC fans with a 7-year full-replacement warranty from the date of original purchase, for customers who bought directly from Festa, with the same call-the-office process as the AC fans and an evaluation program for indirect buyers. The EC installation instructions print a seven year warranty from the date of manufacture, then a closing clause offering five full years from manufacture. Ask Festa which term applies to your fan.

Fan choice is the customer's responsibility on Festa's page, and unused returns carry a 15% restocking fee; the warranty document allows them within 30 days of delivery and refuses a fan that looks as if it ran on an active system. Shipping is FedEx Ground from Cranberry Township, Pennsylvania.

What it costs to run

Electricity is the running cost, and here Festa leaves a gap: none of its pages or documents read for this page states the Hawk EC's watts. The rating label the EC instructions refer to carries it, and a yearly figure is then watts times 8,760 hours, divided by 1,000, times your utility's rate, because the EPA says the fan must run continuously. For scale, Festa's 2022 catalog lists the AC Hawk at 66 W, about 578 kWh a year.

The EPA's guide says fans may last five years or more and that warranties tend not to exceed five years; Festa's seven-year EC term runs past that. Keep an eye on the manometer and retest at least every two years, as the EPA suggests.

Fit and setup

Who it fits, and installation

The fit, then how a system goes in

Who it fits

Good fit if, and look elsewhere if

Good fit if

  • Your home or building covers 2,000 to 3,500 square feet over gravel or another porous fill, the range Festa gives the Hawk EC.
  • You want more air at 1 inch of suction than the AC Hawk offers: Festa's RRNC page lists 175 CFM for the EC against 130 for the AC fan.
  • A longer warranty matters to you; Festa's warranty document gives its EC fans seven years, against five for its AC fans.
  • The site is cold or hot; Festa's EC instructions rate the Hawk EC for ambient temperatures from -13°F to 140°F.

Look elsewhere if

  • You want to dial the speed down; Festa sells that as the AMG Hawk ECS, and its EC instructions say not to add an external speed control.
  • You need Festa's full airflow curve, maximum pressure or wattage before choosing; the Festa pages and documents read for this page give only two airflow points.
  • The slab sits on compact or moist ground such as clay; Festa recommends the Hawk EC for porous sub-slabs such as gravel.
  • You are designing a first system yourself; the EPA recommends a qualified mitigation contractor, and Festa advises a certified and licensed mitigator for fan sizing.

Installation

5 steps

  1. Choosing between the AC Hawk, the Hawk EC and a larger fan is a sizing decision, made from a pressure field test. The EPA recommends a qualified radon mitigation contractor and notes that many states license, certify or register radon professionals; Festa's RRNC page strongly advises a certified and licensed mitigator for fan sizing and installation.
  2. Festa's EC instructions allow the fan to be mounted indoors or outdoors, either vertically with the terminal box cover up or horizontally with the terminal box drain hole toward the ground. It can sit on the piping or be fastened to a supporting structure; on a vertical pipe the installer must stop the pipe from sliding into the motor and impeller. Rigid pipe joins the spigots through flexible connectors and clips that allow servicing and isolate vibration, and short duct runs ending within 60 inches of the fan need guards.
  3. For wiring, the instructions ask that voltage, frequency, phases and power match the unit rating label, with a double-pole isolating switch of at least 1/8 inch (3 mm) contact separation and liquid-tight flexible conduit to the terminal box, all done by a qualified person. They warn against external speed controls and solid-state speed controllers, and say the fan is for use with non-metallic conduit only.
  4. Location is set by the EPA's construction guide: a vertical run of the vent pipe, with the fan and all positively pressurized pipe outside habitable space so a leak cannot pump radon into the home. Festa's EC instructions suggest using EPA recommendations to choose the spot.
  5. Festa's operational checks for the EC fans are the familiar three: duct joints tight and leak-free, a manometer showing vacuum below the maximum recommended operating pressure, and radon tested to EPA protocol. Its FAQ adds that equal oil levels in the manometer mean the fan is not working properly. The EPA wants the warning device visible or audible and a post-mitigation test within 30 days, but no sooner than 24 hours after the fan starts.

To find someone to design and install a system, see radon mitigation professionals, and for how a fan fits into one, how a radon fan works.

Compare

Compare with similar items

The same three rows for each, and the one difference that matters

Compare side by side
  • This page

    Festa AMG Hawk EC

    What it does
    Not stated
    Power
    Not stated
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    This page: The AMG Hawk EC is the electronically commutated version of Festa's 6 inch Hawk, a white fan for 6 inch flexible couplers that Festa sells alone or with a 3 inch or 4 inch installation kit.

  • What it does
    Moves up to 173 CFM
    Power
    Up to 52 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: Another EC fan, with a speed dial built in: Fantech's 2025 brochure lists the Rn 2EC at a 2.0 inch maximum static pressure, 52 W and 173 CFM.

  • What it does
    Moves up to 322 CFM
    Power
    Up to 66 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: The AC Hawk: Festa's RRNC page lists it at 130 CFM at 1.0 inch against the EC's 175, and its 2022 catalog gives it 66 W and a 2.1 inch maximum.

  • What it does
    Moves up to 345 CFM
    Power
    Up to 140 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: Festa's larger AC fan for porous ground: its RRNC page lists the AC Legend at 242 CFM at 1.0 inch, and its catalog gives it 140 W and a 2.6 inch maximum.

More radon fan models6

All radon fan models

Questions

Questions people ask

6 questions about the Festa AMG Hawk EC, answered

Asked about the AMG Hawk EC

What is the difference between the AMG Hawk EC and the AMG Hawk?

The motor, the warranty and, by Festa's own table, the airflow at 1 inch. The Hawk EC has an EC motor and sits on the 7-year EC list of Festa's warranty document; the AMG Hawk is an AC fan on the 5-year list. Festa's RRNC page lists the Hawk EC at 175 CFM at 1.0 inch and the AC Hawk at 130. Festa recommends both for 2,000 to 3,500 square feet over porous ground.

Can I adjust the Hawk EC's speed?

Not on this model. Festa's EC instructions say not to use an external speed control device, and only its ECS models have the built-in potentiometer, turned clockwise to speed the fan up and counterclockwise to slow it. The AMG Hawk ECS is that version of this fan.

How much power does the Hawk EC use?

Festa does not say in the pages and documents read for this page. Its EC instructions point to the unit rating label for the electrical figures, so check the label or ask Festa. Its EC collection page describes the EC fans as energy-efficient without giving a number.

How loud is the AMG Hawk EC?

Festa estimates 60 to 65 dB and says it can vary with the system configuration, with no measuring distance given. It gives the AC Hawk 55 to 60 dB, and for the Hawk ECS it gives 60 to 65 dB at maximum speed, saying a lower speed decreases the noise level.

How long is the warranty on the Hawk EC?

Seven years in Festa's warranty document, from the date of original purchase, for customers who bought directly from Festa, against five years for its AC fans. The EC installation instructions date the seven years from manufacture and also contain a clause offering five full years, so confirm the term with Festa when you buy.

Do I need a professional to install it?

The EPA recommends a qualified radon mitigation contractor and notes that many states license or certify radon professionals, and Festa advises a certified and licensed mitigator for sizing and installation. Festa's EC instructions leave installation work and electrical wiring to a qualified person.

Updated November 27, 2026