Festa
Festa AMG Hawk
High-flow inline radon fan
- Radon fan
- 6 in. Fernco coupler size
- 66 W
Best for, and skip if
Best for you if
- Your home or building covers 2,000 to 3,500 square feet over gravel or similar porous fill, the range Festa names for the Hawk.
- Your mitigator finds air moving easily under the slab and needs volume across a wide area more than strong pull.
Skip it if
- The slab sits on compact or damp ground such as clay; Festa's chart sends that to high suction fans such as the Prowler or Eagle.
- The system needs flow at higher suction; the catalog's Hawk row drops to 42 CFM at 1.5 inches and 12 CFM at 1.75.
Photos: Festa
As an Amazon Associate, Radon411 earns from qualifying purchases.
Amazon and the Amazon logo are trademarks of Amazon.com, Inc. or its affiliates.
See ratings and reviews on Amazon (opens in a new tab)- Pipe size6 in. Fernco coupler size (catalog; product page: fits 6 in. Fernco couplers); Festa's catalog lists a 6 x 3 in. Fernco for 3 in. PVC and a 6 x 4 in. Fernco for 4 in. PVC, and its installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
- Power draw66 W
- Every figure checked against the specifications Festa publishes
- The maker's own performance table, point by point, unranked
About this item
As Festa states it
- Motor: AC
- Pipe size: 6 in. Fernco coupler size (catalog; product page: fits 6 in. Fernco couplers); Festa's catalog lists a 6 x 3 in. Fernco for 3 in. PVC and a 6 x 4 in. Fernco for 4 in. PVC, and its installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
- Max static pressure: 2.1 in w.c.
- Max airflow: 322 CFM
- Max power: 66 W
- Power supply: 115 V, 60 Hz; 66 W; 0.59 A maximum; 2450 RPM
- Airflow at static pressure: 322 CFM at 0.00 in w.c.; 265 at 0.25; 230 at 0.50; 175 at 0.75; 130 at 1.00; 82 at 1.25; 42 at 1.50; 12 at 1.75
- Outdoor use: Rated for outdoor installation
- Warranty: Hassle Free 5 Year Full Replacement Warranty (Festa's 2022 catalog); Festa's warranty document lists it among the AC fans with a 5-year full-replacement warranty from the date of original purchase, extended to customers who bought directly from Festa
The AMG Hawk is Festa's 6 inch AC radon fan for volume, which Festa says offers more airflow than its Maverick, sold in white alone or with a 4 inch or 3 inch installation kit. Festa's 2022 catalog lists it at 322 CFM with no resistance, a maximum pressure of 2.1 inches of water column and 66 W, and Festa recommends it for homes or structures of 2,000 to 3,500 square feet over porous sub-slabs such as gravel.
What you get
On Festa's store the Hawk comes in white, as the fan alone or with Festa's 4 inch or 3 inch installation kit. Either kit holds two white Fernco couplers that fit the fan to 3 inch or 4 inch PVC pipe, a green 5.5 inch radon system manometer, a line cord with connector and system labels. Bought alone, the fan comes with nothing else Festa lists, and the 6 inch Fernco couplers are sold separately.
In the box and running costsHow it works
What it does and how
The suction, the airflow and the housing, then who has checked it
How it works
In our words, from the maker's documents
Mitigation by suction is simple in outline. Per the EPA's consumer guide, a vent fan on the suction pipes pulls radon out from under the home and sends it into the outdoor air, and the same pull leaves a negative pressure beneath the slab. The guide is blunt that the fan should never be turned off: the system works only while it runs.
Loose, clean gravel lets air travel a long way under a slab, which changes what the fan has to do. It no longer fights the ground; it has to move enough air to keep a big area below room pressure. The EPA's guide ties the result to how easily air moves through the crushed rock or soil under the slab. Festa's 2022 selection chart puts homes over 2,200 square feet on ground that is not compact in its high flow group, the Hawk, Legend, Fury and Legend Extreme, and the catalog calls the Hawk great for a step up in volume over the Maverick.
The catalog's quarter-inch row for the Hawk reads 322 CFM at zero, then 265 at 0.25 inch, 230 at 0.5, 175 at 0.75, 130 at 1.0, 82 at 1.25, 42 at 1.5 and 12 at 1.75 inches. Its quickstart page gives 2.1 inches as the maximum pressure. The specification block lists 115 V, 60 Hz, 66 W, 0.59 A maximum, 2450 RPM, a 6 inch Fernco size and 8.2 lbs.
Those electrical figures are the very ones the catalog prints for the 4 inch Maverick, so on paper the two fans draw the same power and spend it differently. The Hawk leads by 62 CFM with no resistance (322 against 260), by 29 at 0.5 inch and by 14 at 1.0 inch, and the gap is down to 2 CFM at 1.5 inches (42 against 40). The Hawk's case is a low-resistance slab with a lot of area to cover, not a slab that needs hard pulling.
Two outside yardsticks help place it. The EPA's construction guide says most contractors have found 90-watt in-line fans adequate for most homes, and names a fan moving 100 cubic feet of air per minute at one inch of water column as sufficient for most applications. The Hawk lists 66 W and 130 CFM at 1.0 inch, the same 130 CFM that Festa's RRNC page gives it in its table of AC fan models.
Festa's catalog describes how the AMG fans are made: EBM-Papst motors engineered in Germany, compression molded housings from Ohio meant to be air and water tight, two halves sealed with silicone and an industrial grade adhesive, assembly in Pennsylvania and lever nuts fitted for the wiring. The installation instructions, whose model list includes the Hawk, say the motor carries an internal overheat device.
Festa sells two other fans under the Hawk name, and neither is this one. The AMG Hawk EC uses an EC motor: the RRNC page lists it at 235 CFM at 0.5 inch and 175 CFM at 1.0 inch, and Festa's warranty document files it with the EC fans. The Hawk LV runs on 12 V, and the catalog lists it at 361 CFM, a 2.88 inch maximum and 74 W.
What the manufacturer says
Festa's own statements, attributed
- Festa saysFesta's 2022 catalog lists the AMG Hawk at a maximum flow of 322 CFM, a maximum pressure of 2.1 inches w.g. and 66 W at 115 V, 60 Hz.
- Festa saysFesta says the AMG Hawk offers more airflow than the AMG Maverick.
- Festa saysFesta states it recommends the AMG Hawk for homes or structures of 2,000 to 3,500 square feet with porous sub-slabs such as gravel.
- Festa saysFesta says the AMG Hawk should run in an estimated 55 to 60 dB range, depending on the system configuration.
- Festa saysFesta states the AMG fans its installation instructions cover, the Hawk among them, can be mounted indoors or outdoors.
- Festa saysFesta's warranty document lists the AMG Hawk among its AC fans, which it states carry a 5-year full-replacement warranty.
These are Festa's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.
Independent evidence
Who checks a device like this
C-NRPP's consumer evaluation covers electronic radon monitors, not mitigation fans, so it has no result for Festa AMG Hawk. The safety listing and performance certification the maker states are under “What the manufacturer says”, and what shows whether any fan is working in your home is a radon test after it is installed.
Festa AMG Hawk
Check price on Amazon (opens in a new tab)Specifications
Specifications
Every figure as the maker states it
The maker's figures
- Type
- Mitigation fan, inline
- Motor
- AC
- Pipe size
- 6 in. Fernco coupler size (catalog; product page: fits 6 in. Fernco couplers); Festa's catalog lists a 6 x 3 in. Fernco for 3 in. PVC and a 6 x 4 in. Fernco for 4 in. PVC, and its installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
- Max static pressure
- 2.1 in w.c.
- Max airflow
- 322 CFM
- Max power
- 66 W
- Power supply
- 115 V, 60 Hz; 66 W; 0.59 A maximum; 2450 RPM
- Speed control
- Not stated by the manufacturer
- Airflow at static pressure
- 322 CFM at 0.00 in w.c.; 265 at 0.25; 230 at 0.50; 175 at 0.75; 130 at 1.00; 82 at 1.25; 42 at 1.50; 12 at 1.75
- Outdoor use
- Rated for outdoor installation
- Warranty
- Hassle Free 5 Year Full Replacement Warranty (Festa's 2022 catalog); Festa's warranty document lists it among the AC fans with a 5-year full-replacement warranty from the date of original purchase, extended to customers who bought directly from Festa
What is in the box
On Festa's store the Hawk comes in white, as the fan alone or with Festa's 4 inch or 3 inch installation kit. Either kit holds two white Fernco couplers that fit the fan to 3 inch or 4 inch PVC pipe, a green 5.5 inch radon system manometer, a line cord with connector and system labels. Bought alone, the fan comes with nothing else Festa lists, and the 6 inch Fernco couplers are sold separately.
Festa's warranty document names the AMG Hawk among its AC fans, covered by a 5-year full-replacement warranty for customers who bought directly from Festa. The process it describes is a call to the office: Festa arranges the return at its own cost when the fan is a year old or less, and for an older fan asks for the terminal box lid alone. Buyers through a mitigation company or installer follow that installer's warranty instead, and other indirect buyers can send the fan back at their own expense for Festa to evaluate, with a comparable replacement if workmanship or materials caused the failure.
Fan choice is the customer's responsibility, Festa's Hawk page says, and unused returns carry a 15% restocking fee; the warranty document sets a 30 day window from delivery for unused returns. Orders ship by FedEx Ground from Cranberry Township, Pennsylvania.
What it costs to run
The Hawk's 66 W is less than half the 140 W the same 2022 catalog lists for the 6 inch Legend. Running all year, as the EPA requires of a radon fan, 66 W comes to about 578 kWh; multiply by your utility's rate per kWh for the cost. Nothing else is consumed: no filter, no service part named by Festa.
Fans wear out. The EPA's guide expects five years or more of life and notes that maker warranties tend not to exceed five years. Watch the manometer between tests, and retest at least every two years, as the EPA suggests.
Airflow at each pressure
Festa's performance table, point by point
| Static pressure | Airflow |
|---|---|
| 0.00 in w.c. | 322 CFM |
| 0.25 in w.c. | 265 CFM |
| 0.50 in w.c. | 230 CFM |
| 0.75 in w.c. | 175 CFM |
| 1.00 in w.c. | 130 CFM |
| 1.25 in w.c. | 82 CFM |
| 1.50 in w.c. | 42 CFM |
| 1.75 in w.c. | 12 CFM |
Airflow falls as the suction the system needs rises. A mitigator matches the fan to pressure measured under the slab.
Fit and setup
Who it fits, and installation
The fit, then how a system goes in
Who it fits
Good fit if, and look elsewhere if
Good fit if
- Your home or building covers 2,000 to 3,500 square feet over gravel or similar porous fill, the range Festa names for the Hawk.
- Your mitigator finds air moving easily under the slab and needs volume across a wide area more than strong pull.
- You are swapping out a fan Festa's 2022 replacement guide pairs with the Hawk: RadonAway's RP260 or RP261, or Fantech's FR150 or RN3.
- The system pipe is 3 or 4 inch PVC, which Festa's Fernco chart joins to the Hawk with a 6 by 3 or 6 by 4 inch coupling.
Look elsewhere if
- The slab sits on compact or damp ground such as clay; Festa's chart sends that to high suction fans such as the Prowler or Eagle.
- The system needs flow at higher suction; the catalog's Hawk row drops to 42 CFM at 1.5 inches and 12 CFM at 1.75.
- You want to set the fan's speed; Festa's instructions say not to use these fans with solid state speed controllers, and Festa sells speed control as separate ECS models.
- You are planning the system on your own; the EPA points to a qualified mitigation contractor, and Festa to a certified and licensed mitigator for sizing.
Installation
5 steps
- Matching a high-flow fan to a slab starts with a pressure field test, which is mitigator work. The EPA recommends a qualified radon mitigation contractor and notes that many states license, certify or register radon professionals; Festa's RRNC page strongly advises a certified and licensed mitigator for fan sizing and installation.
- Festa's instructions give the Hawk two attitudes: upright with the terminal box cover on top, or on its side with the terminal box drain hole pointing at the ground. It may hang from the pipe or be fixed to a supporting structure, provided the installer stops the pipe from sliding into the motor and impeller. Flexible connectors and clips join rigid pipe to the spigots for servicing and vibration isolation, and the catalog's Fernco chart lists a 6 by 3 inch coupling for 3 inch PVC and a 6 by 4 inch coupling for 4 inch PVC.
- Electrical details sit on a rating label inside the terminal box cover, which the supply must match; the catalog lists 115 V, 60 Hz. The instructions ask for a double pole isolating switch with at least 1/8 inch (3 mm) contact separation and liquid tight flexible conduit to the terminal box, and leave all wiring to qualified persons. Because the impeller is unguarded, the fan must stay out of reach of people and animals, with guards on short duct runs that end within 60 inches of it.
- Location follows the EPA's construction guide: the fan in a vertical run of pipe, and the fan and every positively pressurized length of vent pipe outside the habitable space, so a leak at the housing or a joint cannot push radon indoors. Festa's AC fans page says these fans are typically mounted outside the home.
- Commissioning, in Festa's instructions, means tight duct joints, a manometer reading below the maximum recommended operating pressure and a radon test to EPA protocol. Festa's FAQ adds that equal oil levels on the manometer mean the fan is not working properly. The EPA asks for a warning device that can be seen or heard easily and a post-mitigation test within 30 days, but no sooner than 24 hours after the fan starts.
To find someone to design and install a system, see radon mitigation professionals, and for how a fan fits into one, how a radon fan works.
Compare
Compare with similar items
The same three rows for each, and the one difference that matters
Compared with similar products: 1 of 4
More radon fan models6
All radon fan modelsMore radon fan models: 1 of 6
Questions
Questions people ask
5 questions about the Festa AMG Hawk, answered
Asked about the AMG Hawk
How much air does the AMG Hawk move?
Festa's 2022 catalog lists 322 CFM at 0 inches of water column, 265 at 0.25, 230 at 0.5, 175 at 0.75, 130 at 1.0, 82 at 1.25, 42 at 1.5 and 12 at 1.75, and gives 2.1 inches as the maximum pressure.
Why choose the Hawk over the Maverick if they use the same power?
For area. The catalog gives both 66 W, but the Hawk's 6 inch fan moves more air while suction is low: 230 CFM against 201 at 0.5 inch and 130 against 116 at 1.0. Festa sizes the Hawk for 2,000 to 3,500 square feet and the Maverick for 500 to 2,200, both over porous ground. Past about 1.5 inches the two rows meet, so neither suits a slab that needs hard pulling.
Is the AMG Hawk the same as the AMG Hawk EC?
No. The Hawk is an AC fan on Festa's 5-year list; the Hawk EC has an EC motor and sits on the 7-year list in Festa's warranty document. Festa's RRNC page lists the Hawk at 130 CFM at 1.0 inch and the Hawk EC at 175 CFM. Each has its own product page.
How loud is the AMG Hawk?
Festa estimates 55 to 60 dB, adding that it can vary with the system configuration, and names no measuring distance. That is the same range Festa gives the Maverick, and below the 60 to 65 dB it gives the Legend.
Do I need a professional to install it?
For a new system, the EPA's advice is a qualified contractor, and many states license or certify radon professionals; Festa also recommends a certified and licensed mitigator. Even a like-for-like swap means mains wiring, which Festa's instructions leave to qualified persons.
What to do next
- See every radon fan we coverEach maker's published pressure, airflow and power, side by side.
- Find a mitigation professionalMost systems are designed and installed by one; some states require a license.
- Understand the fanWhat the fan does in a system, and when one needs replacing.
- Test after it runsA short-term test after installation shows whether the system works.
Updated November 27, 2026