Radon fan![]()
AMG Phoenix EC 4 inch EC radon fan for newer homes
- 4 in. Fernco
- 110 W
Max airflow: 210 CFM
Max pressure: 3.15 in w.c.
Festa
Slimline inline radon fan
Best for you if
Skip it if
Photos: Festa
As an Amazon Associate, Radon411 earns from qualifying purchases.
Amazon and the Amazon logo are trademarks of Amazon.com, Inc. or its affiliates.
See ratings and reviews on Amazon (opens in a new tab)As Festa states it
The AMG Patriot is the AC radon fan Festa calls the slimline design: a white fan for a 4 inch Fernco coupling, sold alone or with Festa's 4 inch or 3 inch installation kit. Festa's 2022 catalog lists it at 195 CFM with no resistance, a maximum pressure of 2.0 inches of water column and 90 W, and Festa recommends it for newer, moderate-sized homes of 500 to 2,200 square feet over porous sub-slabs such as gravel.
Festa lists the Patriot only in white, as the fan alone, with its 4 inch installation kit or with its 3 inch kit. A kit adds two Fernco couplers that fit the fan to 3 inch or 4 inch PVC pipe, a green 5.5 inch radon system manometer, a line cord with connector and system labels. Festa lists nothing more with the bare fan, and sells the 4 inch Fernco couplers separately.
In the box and running costsHow it works
The suction, the airflow and the housing, then who has checked it
In our words, from the maker's documents
The fan in a sub-slab system is its engine, and it has no off season. According to the EPA's guide, it draws radon gas through the suction pipes from below the home, releases it into the outdoor air and creates a vacuum beneath the slab as it goes; the guide says it must run continuously for the system to work.
The Patriot belongs to the ordinary case. Festa's 2022 selection chart sends homes under 2,200 square feet on ground that is not compact to its primary fans, the Maverick, Patriot and Spirit, and its catalog recommends the Patriot for structures of 500 to 2,220 square feet over porous subslab such as gravel, calling it great for most moderately sized, newer built homes. The product page puts the top of that range at 2,200.
Its catalog row starts in eighths of an inch: 195 CFM at zero, 183 at 0.125 inch and 174 at 0.25, then 155 at 0.5, 131 at 0.75, 107 at 1.0, 81 at 1.25, 55 at 1.5 and 24 at 1.75, with a maximum of 2.0 inches. The specification block lists 115 V, 60 Hz, 90 W, 0.80 A maximum, 2763 RPM, a 4 inch Fernco size and 11.5 lbs.
The EPA's construction guide offers two rules of thumb that the Patriot lines up with almost exactly. It says most contractors have found 90-watt in-line fans adequate for most homes, and it treats a fan moving 100 cubic feet of air per minute at one inch of water column as sufficient for most applications. The Patriot is listed at 90 W and 107 CFM at 1.0 inch.
Festa's own replacement guide offers the Patriot as the alternative to its Maverick: for installed XP151, XP201, RP145, FR100, HP190, HP2190, RN2 and RN2SL fans it lists the AMG Maverick or AMG Patriot. Side by side in the catalog, the Maverick moves more air at low suction (260 CFM against 195 free, 201 against 155 at 0.5 inch) for 66 W, while the Patriot's row runs a little higher from 1.25 inches on, 81 CFM to 75 and then 55 to 40 at 1.5 inches. Fantech's 2025 brochure, cross-referencing its own fans, lists the Patriot against its Rn 2SL Slimline.
Festa's AMG installation instructions open with a model list that does not include the Patriot, yet their installation section is headed for the AMG Patriot and says the FME AMG Patriot fan can be mounted indoors or outdoors. The Patriot's product page gives no noise estimate, and it shows the line Not For Use In Unattended Areas without explaining it.
Festa's own statements, attributed
These are Festa's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.
Who checks a device like this
C-NRPP's consumer evaluation covers electronic radon monitors, not mitigation fans, so it has no result for Festa AMG Patriot. The safety listing and performance certification the maker states are under “What the manufacturer says”, and what shows whether any fan is working in your home is a radon test after it is installed.
Festa AMG Patriot
Check price on Amazon (opens in a new tab)Specifications
Every figure as the maker states it
Festa lists the Patriot only in white, as the fan alone, with its 4 inch installation kit or with its 3 inch kit. A kit adds two Fernco couplers that fit the fan to 3 inch or 4 inch PVC pipe, a green 5.5 inch radon system manometer, a line cord with connector and system labels. Festa lists nothing more with the bare fan, and sells the 4 inch Fernco couplers separately.
In Festa's warranty document the AMG Patriot is on the AC list, with a 5-year full-replacement warranty extended to customers who bought from Festa directly. Festa says a claim is a phone call: it returns a fan a year old or less at its own expense, and for an older one asks only for the terminal box lid. A fan bought through a mitigation company or installer follows that installer's warranty; other indirect buyers may send it back at their own cost for Festa to evaluate, and get a comparable replacement if workmanship or materials were at fault.
The buyer is responsible for choosing the correct fan, Festa's Patriot page says, and unused returns carry a 15% restocking fee; its warranty document limits them to 30 days from delivery. Festa ships by FedEx Ground from Cranberry Township, Pennsylvania.
At 90 W, running all the time as the EPA says a radon fan must, the Patriot uses about 788 kWh a year by the catalog's figure, some 210 kWh more than the 66 W Maverick. Multiply by your utility's rate per kWh for the cost. Nothing else is consumed.
Plan for an eventual replacement: the EPA's guide says fans may last five years or more, and that maker warranties tend not to exceed five years. The manometer is the routine check, and the EPA suggests retesting at least every two years.
Festa's performance table, point by point
| Static pressure | Airflow |
|---|---|
| 0.00 in w.c. | 195 CFM |
| 0.13 in w.c. | 183 CFM |
| 0.25 in w.c. | 174 CFM |
| 0.50 in w.c. | 155 CFM |
| 0.75 in w.c. | 131 CFM |
| 1.00 in w.c. | 107 CFM |
| 1.25 in w.c. | 81 CFM |
| 1.50 in w.c. | 55 CFM |
| 1.75 in w.c. | 24 CFM |
Airflow falls as the suction the system needs rises. A mitigator matches the fan to pressure measured under the slab.
Fit and setup
The fit, then how a system goes in
Good fit if, and look elsewhere if
Good fit if
Look elsewhere if
5 steps
To find someone to design and install a system, see radon mitigation professionals, and for how a fan fits into one, how a radon fan works.
Compare
The same three rows for each, and the one difference that matters
Compared with similar products: 1 of 4
More radon fan models: 1 of 6
Questions
5 questions about the Festa AMG Patriot, answered
Festa's 2022 catalog lists 195 CFM at 0 inches of water column, 183 at 0.125, 174 at 0.25, 155 at 0.5, 131 at 0.75, 107 at 1.0, 81 at 1.25, 55 at 1.5 and 24 at 1.75, and a maximum pressure of 2.0 inches.
Festa treats them as alternatives for the same job: its replacement guide lists the Maverick or the Patriot for the same installed fans, and it sizes both for 500 to 2,200 square feet over porous ground. On the catalog's figures, the Maverick moves more air below about 1.25 inches for less power, 66 W against 90 W, and the Patriot holds slightly more flow from 1.25 to 1.75 inches. The housing differs too: Festa calls the Patriot its slimline design.
Its AMG installation instructions include a section headed for the AMG Patriot, which says it can be mounted indoors or outdoors and covers mounting, wiring and operational checks, although the model list at the top of the same document does not name it. Ask Festa for its current Patriot sheet if you want one that names the fan throughout.
Festa does not give a figure on the Patriot's page. For its Maverick, the fan its replacement guide treats as the Patriot's alternative, Festa estimates 55 to 60 dB, varying with the system configuration. Mounting outdoors, which the instructions allow, keeps fan noise out of the house.
It is what both the EPA and Festa advise: the EPA a qualified mitigation contractor, licensed or certified where the state requires it, and Festa a certified and licensed mitigator to size and fit the fan. Festa's instructions also reserve the 115 V wiring for a qualified person.
Updated November 27, 2026