Radon fan![]()
AMG Patriot slimline inline radon fan
- 4 in. Fernco coupler size
- 90 W
Max airflow: 195 CFM
Max pressure: 2.0 in w.c.
Festa
4 inch EC radon fan for newer homes
Best for you if
Skip it if
Photos: Festa
As an Amazon Associate, Radon411 earns from qualifying purchases.
Amazon and the Amazon logo are trademarks of Amazon.com, Inc. or its affiliates.
See ratings and reviews on Amazon (opens in a new tab)As Festa states it
The AMG Phoenix EC is a 4 inch EC radon fan that Festa designs for newer homes with porous sub-slabs such as gravel and footprints of 500 to 2,200 square feet. Festa's product page lists a 3.15 inch w.g. maximum pressure, 210 CFM maximum flow and 110 W, an estimated 50 to 55 dB, and a 7 year warranty on all of its AMG EC fans.
Festa's Phoenix EC page lists three styles: fan only, a 3 inch installation kit and a 4 inch installation kit. A kit adds two white flexible couplers that fit the fan to either 3 inch or 4 inch system piping, a green 5.5 inch radon system manometer, a line cord with connector and system labels.
In the box and running costsHow it works
The suction, the airflow and the housing, then who has checked it
In our words, from the maker's documents
Many newer homes already have the bones of a radon system. The EPA's guide to radon-resistant construction describes a passive stack from below the slab to the roof, with a junction box in the attic so an in-line fan can be added later, and says a passive system can be upgraded to an active one by installing that fan. The Phoenix EC is pitched at this kind of home: Festa says its motor is designed for newer homes with porous sub-slabs such as gravel.
Festa's numbers for the fan are a 3.15 inch w.g. maximum pressure and 210 CFM maximum flow, on 110 W, 115 V at 60 Hz, 1.45 A at most and 3,602 RPM, with a 4 inch Fernco. The page publishes no airflow at intermediate pressures, so the CFM it would hold at the one inch the EPA's guide uses as a yardstick, where a fan moving 100 cubic feet a minute should be sufficient for most applications, is not given.
Festa already sells a 4 inch EC fan for the same homes, the AMG Maverick EC, which it recommends for moderate-sized, newer homes of 500 to 2,200 square feet over porous sub-slabs. Its RRNC page gives the Maverick EC 150 CFM at 0.5 inch and 117 CFM at 1.0 inch but no maximums; the Phoenix EC page gives maximums but no points, so the two are published on different scales.
Against Festa's 4 inch AC fans the Phoenix EC's maximum pressure is higher: the 2022 catalog lists the AMG Maverick at 2.21 inches and 260 CFM on 66 W, and the AMG Patriot at 2.0 inches and 195 CFM on 90 W. The Phoenix EC's listed 110 W is above both AC fans' figures, and Festa's page does not say at what operating point that wattage applies.
Festa's EC collection page describes its electronically commutated fans as brushless, with less wear, longer life and lower maintenance, and the Phoenix EC page says the fan boasts impressive performance while offering superior longevity. Festa calls the motor Swiss-engineered and gives no service-life figure.
Festa's own statements, attributed
These are Festa's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.
Who checks a device like this
C-NRPP's consumer evaluation covers electronic radon monitors, not mitigation fans, so it has no result for Festa AMG Phoenix EC. The safety listing and performance certification the maker states are under “What the manufacturer says”, and what shows whether any fan is working in your home is a radon test after it is installed.
Festa AMG Phoenix EC
Check price on Amazon (opens in a new tab)Specifications
Every figure as the maker states it
Festa's Phoenix EC page lists three styles: fan only, a 3 inch installation kit and a 4 inch installation kit. A kit adds two white flexible couplers that fit the fan to either 3 inch or 4 inch system piping, a green 5.5 inch radon system manometer, a line cord with connector and system labels.
Festa's warranty document gives EC fans seven years of full replacement from the date of original purchase, for direct customers. Builders who practise radon-resistant new construction with Festa AMG fans can transfer the manufacturer's warranty to the home buyer, who then files the builder's warranty card with Festa when a claim arises.
The choice of fan rests with the buyer on Festa's page; unused returns carry a 15% restocking fee, and orders ship by FedEx Ground from Cranberry Township, Pennsylvania.
Running costs are electricity only. At Festa's 110 W rating, continuous operation is about 964 kWh a year (110 x 8,760 / 1,000); the AC Maverick's catalog 66 W works out to about 578 kWh. Multiply by your rate per kWh; since Festa does not say at what operating point its 110 W applies, the result is an estimate.
The EPA's guide says fan systems slightly increase the electric bill, that fans may last five years or more, and that the home should be retested at least every two years; Festa's seven-year EC term runs past the five years the EPA says warranties tend not to exceed.
Fit and setup
The fit, then how a system goes in
Good fit if, and look elsewhere if
Good fit if
Look elsewhere if
4 steps
To find someone to design and install a system, see radon mitigation professionals, and for how a fan fits into one, how a radon fan works.
Compare
The same three rows for each, and the one difference that matters
Compared with similar products: 1 of 5
More radon fan models: 1 of 6
Questions
5 questions about the Festa AMG Phoenix EC, answered
Festa designs it for newer homes with porous sub-slabs such as gravel and footprints of 500 to 2,200 square feet. That matches the homes the EPA's construction guide describes, where a passive stack and attic junction box let an in-line fan be added later.
Festa places both 4 inch EC fans in newer homes of 500 to 2,200 square feet over porous ground. It estimates 50 to 55 dB for the Phoenix EC and 60 to 65 dB for the Maverick EC, and publishes maximum figures for one and RRNC points for the other, so Festa's phone line is the place to compare curves.
No. Festa's Phoenix ECS is the Phoenix EC with a built-in speed potentiometer added, which Festa says lets the installer dial in the vacuum pressure a slab needs.
For builder installs, yes: Festa's warranty document lets builders using its AMG fans in radon-resistant new construction transfer the manufacturer's warranty to the buyer, who fills in the warranty card from the builder when making a claim.
The fan itself takes a 4 inch Fernco. Festa's installation kits include flexible couplers that fit it to either 3 inch or 4 inch system piping.
Updated November 27, 2026