Skip to content

Festa

Festa AMG Spirit

Low-power inline radon fan

  • Radon fan
  • 5 in. Fernco coupler size
  • 27 W

Best for, and skip if

Best for you if

  • The house is newer, its footprint is 1,200 square feet or less and it sits on gravel, the case Festa writes the Spirit for.
  • Your mitigator measured low suction, under the Spirit's 0.9 inch maximum, with air moving easily below the slab.

Skip it if

  • The home is larger than about 1,200 square feet; Festa sizes its other primary fans, the Maverick and Patriot, for 500 to 2,200 square feet, at 260 and 195 CFM free air in its catalog.
  • The slab needs suction near or past one inch; the Spirit's catalog row ends at 0.8 inches and its maximum is 0.9.
  • Festa AMG Spirit

Photos: Festa

  • Pipe size5 in. Fernco coupler size (catalog; product page: fits 5 in. Fernco couplers); Festa's catalog lists a 5 x 3 in. Fernco for 3 in. PVC and a 5 x 4 in. Fernco for 4 in. PVC, and its installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
  • Power draw27 W
  • Every figure checked against the specifications Festa publishes
  • The maker's own performance table, point by point, unranked
Tests that check it works

About this item

As Festa states it

  • Motor: AC
  • Pipe size: 5 in. Fernco coupler size (catalog; product page: fits 5 in. Fernco couplers); Festa's catalog lists a 5 x 3 in. Fernco for 3 in. PVC and a 5 x 4 in. Fernco for 4 in. PVC, and its installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
  • Max static pressure: 0.9 in w.c.
  • Max airflow: 121 CFM
  • Max power: 27 W
  • Power supply: 115 V, 60 Hz; 27 W; 0.24 A maximum; 3250 RPM
  • Airflow at static pressure: 121 CFM at 0.00 in w.c.; 114 at 0.10; 106 at 0.20; 98 at 0.30; 88 at 0.40; 76 at 0.50; 62 at 0.60; 46 at 0.70; 26 at 0.80
  • Outdoor use: Rated for outdoor installation
  • Warranty: Hassle Free 5 Year Full Replacement Warranty (Festa's 2022 catalog); Festa's warranty document lists it among the AC fans with a 5-year full-replacement warranty from the date of original purchase, extended to customers who bought directly from Festa

The AMG Spirit is the small one in Festa's AC radon fan line, which Festa calls the quiet and compact fan: a 5 inch Fernco model in white or grey, sold alone or with an installation kit. Festa's 2022 catalog lists it at 121 CFM with no resistance, a maximum pressure of 0.9 inches of water column and 27 W, and Festa recommends it for small, newer homes of 1,200 square feet or less built over porous sub-slabs such as gravel.

What you get

Festa's Spirit page offers white or grey, each as the fan only or with an installation kit. The kit holds two Fernco couplers that fit the fan to 3 inch or 4 inch PVC pipe, white with a white fan and grey with a grey one, plus a green 5.5 inch radon system manometer, a line cord with connector and system labels. The fan-only style lists nothing else, and Festa sells its 5 inch Fernco couplers separately.

In the box and running costs

How it works

What it does and how

The suction, the airflow and the housing, then who has checked it

How it works

In our words, from the maker's documents

A radon fan's job, in the EPA's words, is to draw soil gas from beneath the home through the suction pipes and release it outdoors while it lowers the pressure under the slab. Because that pressure difference is the protection, the EPA's guide says the fan must run all the time.

How much fan a house needs depends on what the air has to cross. Under a small, recently built slab laid over clean gravel, soil gas flows to the suction point with little resistance, and a modest fan can hold the whole footprint below room pressure. That is the case Festa designed the Spirit for: its catalog says structures of 1,200 square feet or less over porous subslab such as gravel, great for small, newly built homes. On the catalog's selection chart it is one of three primary fans for smaller homes on ground that is not compact, with the Maverick and Patriot.

The catalog draws the Spirit's curve in tenths of an inch: 121 CFM at zero, 114 at 0.1, 106 at 0.2, 98 at 0.3, 88 at 0.4, 76 at 0.5, 62 at 0.6, 46 at 0.7 and 26 at 0.8, with a maximum pressure of 0.9 inches. Its specifications read 115 V, 60 Hz, 27 W, 0.24 A maximum, 3250 RPM, a 5 inch Fernco size and 5.2 lbs. Festa's RRNC page carries the 0.5 inch point, 76 CFM, in its first table of AC fan models.

Those numbers set the Spirit's limits plainly. The EPA's construction guide names a fan that moves 100 cubic feet of air per minute at one inch of water column as sufficient for most applications, and says most contractors have found 90-watt in-line fans adequate for most homes. The Spirit's row ends before one inch, at 0.8, and its 27 W is under a third of 90. It is a fan for the easy slab, not the average one, which matches Festa's own fit.

Festa's catalog says its AMG fans use EBM-Papst motors made and engineered in Germany and compression molded housings made in Ohio, the halves sealed with silicone and industrial grade adhesive and assembled in Pennsylvania, with lever nuts already attached for wiring. The AMG installation instructions list the Spirit first among the models they cover and say the motor has an internal overheat device.

What the manufacturer says

Festa's own statements, attributed

  • Festa saysFesta's 2022 catalog lists the AMG Spirit at a maximum flow of 121 CFM, a maximum pressure of 0.9 inches w.g. and 27 W at 115 V, 60 Hz.
  • Festa saysFesta describes the AMG Spirit as the quiet and compact fan and says it is available in white or grey.
  • Festa saysFesta states it recommends the AMG Spirit for small, newer homes or structures of 1,200 square feet or less built on porous sub-slabs such as gravel.
  • Festa saysFesta estimates the Spirit's sound at 55 to 60 dB and says the figure changes with the system configuration.
  • Festa saysFesta states in its AMG installation instructions, which list the Spirit first, that the fans can go indoors or outdoors.
  • Festa saysFesta's warranty document names the AMG Spirit first among its AC fans and states a 5-year full-replacement term for them.

These are Festa's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.

Independent evidence

Who checks a device like this

C-NRPP's consumer evaluation covers electronic radon monitors, not mitigation fans, so it has no result for Festa AMG Spirit. The safety listing and performance certification the maker states are under “What the manufacturer says”, and what shows whether any fan is working in your home is a radon test after it is installed.

Specifications

Specifications

Every figure as the maker states it

Compare side by side

The maker's figures

Type
Mitigation fan, inline
Motor
AC
Pipe size
5 in. Fernco coupler size (catalog; product page: fits 5 in. Fernco couplers); Festa's catalog lists a 5 x 3 in. Fernco for 3 in. PVC and a 5 x 4 in. Fernco for 4 in. PVC, and its installation kit couplers fit the fan to 3 in. or 4 in. PVC pipe
Max static pressure
0.9 in w.c.
Max airflow
121 CFM
Max power
27 W
Power supply
115 V, 60 Hz; 27 W; 0.24 A maximum; 3250 RPM
Speed control
Not stated by the manufacturer
Airflow at static pressure
121 CFM at 0.00 in w.c.; 114 at 0.10; 106 at 0.20; 98 at 0.30; 88 at 0.40; 76 at 0.50; 62 at 0.60; 46 at 0.70; 26 at 0.80
Outdoor use
Rated for outdoor installation
Warranty
Hassle Free 5 Year Full Replacement Warranty (Festa's 2022 catalog); Festa's warranty document lists it among the AC fans with a 5-year full-replacement warranty from the date of original purchase, extended to customers who bought directly from Festa

What is in the box

Festa's Spirit page offers white or grey, each as the fan only or with an installation kit. The kit holds two Fernco couplers that fit the fan to 3 inch or 4 inch PVC pipe, white with a white fan and grey with a grey one, plus a green 5.5 inch radon system manometer, a line cord with connector and system labels. The fan-only style lists nothing else, and Festa sells its 5 inch Fernco couplers separately.

The AMG Spirit is the first name on the AC list in Festa's warranty document, which gives those fans a 5-year full-replacement warranty for customers who bought directly from Festa. A call to the office starts a claim; Festa pays to bring back a fan a year old or less and asks only for the terminal box lid on an older one. Buyers through a mitigation company or installer rely on that installer's warranty, and other indirect buyers can ship the fan to Festa at their own expense for evaluation, with a comparable replacement if workmanship or materials caused the failure. Festa's 2022 catalog advertises the same Hassle Free 5 Year Full Replacement Warranty.

Festa's page says choosing the fan is the buyer's responsibility and charges a 15% restocking fee on unused returns; its warranty document allows those returns within 30 days of delivery. Orders go by FedEx Ground from Cranberry Township, Pennsylvania.

What it costs to run

The Spirit's appeal is its draw. At the catalog's 27 W, running continuously as the EPA requires, it uses about 237 kWh a year, against about 578 kWh for the 66 W Maverick in the same catalog. Multiply by your utility's rate per kWh for the yearly cost; there are no filters or other consumables.

A fan is still a wear part. The EPA's guide says fans may last five years or more and that maker warranties tend not to exceed five years, and it suggests retesting at least every two years, with the manometer as the everyday check.

Airflow at each pressure

Festa's performance table, point by point

Static pressureAirflow
0.00 in w.c.
121 CFM
0.10 in w.c.
114 CFM
0.20 in w.c.
106 CFM
0.30 in w.c.
98 CFM
0.40 in w.c.
88 CFM
0.50 in w.c.
76 CFM
0.60 in w.c.
62 CFM
0.70 in w.c.
46 CFM
0.80 in w.c.
26 CFM

Airflow falls as the suction the system needs rises. A mitigator matches the fan to pressure measured under the slab.

Fit and setup

Who it fits, and installation

The fit, then how a system goes in

Who it fits

Good fit if, and look elsewhere if

Good fit if

  • The house is newer, its footprint is 1,200 square feet or less and it sits on gravel, the case Festa writes the Spirit for.
  • Your mitigator measured low suction, under the Spirit's 0.9 inch maximum, with air moving easily below the slab.
  • You are replacing a fan Festa's 2022 replacement guide pairs with the Spirit: RadonAway's RP140, Fantech's HP2133 or Fantech's RN1.
  • You would like a grey fan rather than white; Festa sells the Spirit in both, with couplers to match in its kits.

Look elsewhere if

  • The home is larger than about 1,200 square feet; Festa sizes its other primary fans, the Maverick and Patriot, for 500 to 2,200 square feet, at 260 and 195 CFM free air in its catalog.
  • The slab needs suction near or past one inch; the Spirit's catalog row ends at 0.8 inches and its maximum is 0.9.
  • The ground under the slab is compact or damp, such as clay; Festa's chart sends that to high suction fans such as the Prowler or Eagle.
  • You mean to install it yourself as a first system; the EPA advises hiring a qualified mitigation contractor, and Festa a certified and licensed mitigator to size the fan.

Installation

5 steps

  1. A small fan only works if the slab really is easy, and only a diagnostic shows that. EPA guidance is to have a qualified radon mitigation contractor do the work, and many states require such contractors to be licensed, certified or registered; Festa's RRNC page says it strongly advises a certified, licensed mitigator for sizing and installing fans.
  2. The Spirit's 5 inch outlet is an uncommon size, so the couplings matter: Festa's Fernco chart lists a 5 by 3 inch coupling for 3 inch PVC and a 5 by 4 inch coupling for 4 inch PVC. The instructions allow two positions, vertical with the terminal box cover facing up or horizontal with its drain hole facing down, and mounting on the pipe or on a supporting structure as long as the pipe cannot slide into the motor and impeller.
  3. Electrically the Spirit is light, 0.24 A at 115 V, 60 Hz in the catalog, but Festa's instructions still leave wiring to qualified persons, through a double pole isolating switch with at least 1/8 inch (3 mm) contact separation and liquid tight flexible conduit, with the power left off until installation is complete. Guards are needed where short duct runs end within 60 inches of the unguarded impeller. Festa's Spirit page also carries the line Not For Use In Unattended Areas, which it does not explain; ask Festa what it means for your site.
  4. For location, the EPA's construction guide puts the fan in a vertical run of pipe and keeps it, with all positively pressurized pipe, outside habitable space. Festa's AC fans page says its AC fans are typically mounted outside the home.
  5. Commissioning follows Festa's operational checks: tight, leak-free joints, a manometer reading below the maximum recommended operating pressure, and a radon test to EPA protocol. Festa's FAQ says equal oil levels on the manometer mean the fan is not working properly. The EPA wants the warning device where it can be seen or heard easily, and a post-mitigation test within 30 days of installation, no sooner than 24 hours after the fan is on.

To find someone to design and install a system, see radon mitigation professionals, and for how a fan fits into one, how a radon fan works.

Compare

Compare with similar items

The same three rows for each, and the one difference that matters

Compare side by side
  • This page

    Festa AMG Spirit

    What it does
    Moves up to 121 CFM
    Power
    Up to 27 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    This page: The AMG Spirit is the small one in Festa's AC radon fan line, which Festa calls the quiet and compact fan: a 5 inch Fernco model in white or grey, sold alone or with an installation kit.

  • What it does
    Moves up to 174 CFM
    Power
    Up to 59 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: Fantech's mid-range fan: its 2025 brochure lists the Rn 2 at a maximum static pressure of 2.0 inches, 59 W and 174 CFM, and its Rn 1 at 0.9 inches and 20 W.

  • What it does
    Moves up to 260 CFM
    Power
    Up to 66 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: Festa's next primary fan up: its catalog lists the 4 inch Maverick at 260 CFM free air, a 2.21 inch maximum and 66 W.

  • What it does
    Moves up to 138 CFM
    Power
    Up to 21 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: A fan Festa's replacement guide swaps for the Spirit: RadonAway lists its 4 inch RP140c at 17 to 21 W, a 0.7 inch recommended maximum operating pressure and 138 CFM at 0 inches.

More radon fan models6

All radon fan models

Questions

Questions people ask

5 questions about the Festa AMG Spirit, answered

Asked about the AMG Spirit

How much air does the AMG Spirit move?

Festa's 2022 catalog lists, in CFM: 121 at 0 inches of water column, 114 at 0.1, 106 at 0.2, 98 at 0.3, 88 at 0.4, 76 at 0.5, 62 at 0.6, 46 at 0.7 and 26 at 0.8, with a maximum pressure of 0.9 inches.

Is the AMG Spirit big enough for my house?

Only for a small, easy one by Festa's own measure: 1,200 square feet or less over porous sub-slabs such as gravel, and newer construction. Its catalog row stops short of one inch of suction, so a slab that needs more pull than that is outside its range. A mitigator's pressure readings settle the question.

Which installed fans does Festa say the Spirit replaces?

Festa's 2022 replacement guide pairs the AMG Spirit with installed RP140, HP2133 and RN1 fans. Fantech's 2025 brochure lists its Rn 1 at a 0.9 inch maximum static pressure and 20 W, figures close to the Spirit's 0.9 inches and 27 W.

How loud is the AMG Spirit?

Festa estimates 55 to 60 dB and says it can vary with the system configuration; it names no measuring distance. That is the same range it gives the Maverick. An outdoor mount, which Festa's instructions allow, keeps the sound outside.

Do I need a professional to install it?

Both the EPA, which points homeowners to qualified contractors and notes that many states license or certify them, and Festa, which wants a certified and licensed mitigator choosing and fitting its fans, say so. Small as it is, the Spirit still runs on mains power, and Festa's instructions keep that wiring with a qualified person.

Updated November 27, 2026