RadonAway
RadonAway Easy Read U-Tube Manometer (50036)
Extended-range U-tube radon system manometer
- System indicator
Best for, and skip if
Best for you if
- Your system runs on a RadonAway GX4, GX5 or GX5A, the fans RadonAway names for this gauge.
- Your installer recorded a normal reading near or above 4 inches, too close to the top of a 0 to 4.5 inch tube.
Skip it if
- Your fan runs well below 4 inches; RadonAway's standard Easy Read, part 50017, reads 0 to 4.5 inches.
- Your system pulls beyond 6.5 inches, past the top of this scale; a gauge with a longer range fits.
Photos: RadonAway
As an Amazon Associate, Radon411 earns from qualifying purchases.
Amazon and the Amazon logo are trademarks of Amazon.com, Inc. or its affiliates.
See ratings and reviews on Amazon (opens in a new tab)- Every figure checked against the specifications RadonAway publishes
- The maker's own figures and limits, shown the same way for every part, unranked
About this item
As RadonAway states it
- What it reads: Vacuum in the radon system's pipe, read from blue fluid in a U-tube against a 0 to 6.5 in. scale; does not measure radon
- Range: 0 to 6.5 in. WC; for fans whose recommended and maximum operating pressures go above 4 in. WC (GX4, GX5, GX5A; optional for the EC6)
- Made of: U-tube manometer with non-toxic fluid, adjustable zero and a molded scale curved to fit the system pipe (catalog features for RadonAway's U-tubes)
- Package: Manometer with tubing and 2 self-tap screws, installation instructions, label package (4 pipe labels, fan circuit label in 2 sizes, system label, sump label), system information brochure and 10-page OM&M document, clear plastic bag with twist tie; 50 per case
This is RadonAway's longer Easy Read U-tube, part 50036: a blue U-tube gauge with a 0 to 6.5 inch water column scale, made for the high-pressure GX radon fans whose operating pressures run past the 4.5 inch top of its standard gauge. It comes with tubing, two self-tap screws and a system information document, and shows whether the fan is pulling suction in the pipe. RadonAway says plainly that it does not measure radon levels.
What you get
RadonAway's catalog lists the U-tube packet: the Easy Read U-tube manometer with tubing and 2 self-tap screws, installation instructions, a system and component label package (4 pipe labels, a fan circuit label in 2 sizes, a system label and a sump label), a system information brochure, and a clear plastic bag with a twist tie for hanging the information on the system. The trade page adds that the 10-page OM&M and system information document is included. The catalog lists the 50036 in blue, 50 to a case.
In the box and running costsHow it works
What it does and how
What it is made of and the job it does in a system, then who has checked it
How it works
In our words, from the maker's documents
A U-tube gauge on a radon pipe works by suction. Minnesota's health department describes it: the u-tube manometer uses colored fluid in a tube to visually indicate the radon system is working; a small tube connects to a hole in the radon pipe and the suction from the fan pulls the fluid up. The stronger the fan pulls, the farther apart the two columns stand, and the scale reads that gap in inches of water column.
That is where the length of the tube matters. RadonAway's page says the 50036 has an extended 0 to 6.5 inch scale for high-pressure radon fans whose recommended and maximum operating pressures go above 4 inches, leaving little or no headroom on a standard 0 to 4.5 inch Easy Read U-tube. Its 2023/2024 catalog gives the numbers behind that: a recommended maximum operating pressure of 4.8 inches for the GX4, on 3 inch duct, and 5.0 inches for the GX5A, on 4 inch duct, and it says the 6.5 inch gauge was introduced for the GX5A, which is capable of achieving 5 inches of vacuum. RadonAway's standard gauge, by its own page, is not suitable above 4.5 inches.
RadonAway's two documents name slightly different fans. The trade page says the gauge is intended for the GX4 (P/N 28585), GX5 (P/N 28586) and GX5A (P/N 28536), and optional for the EC6 variable speed fan (P/N 28625); the catalog names the GX5A. Either way the gauge is for systems built around RadonAway's high-pressure GX fans. The catalog prints one feature list for both sizes: it reads 0 to 6.5 inches for the 6.5 inch U-tube, with non-toxic fluid, an adjustable zero and a molded scale curved to fit the system pipe.
The limit is the same as for every gauge of its kind. RadonAway's catalog marks its U-tubes with the note that the device does not measure radon levels, and Minnesota says such a monitor shows there is suction in the pipe, not radon. A reading inside its usual range says the fan is pulling as it did when the system was commissioned; only a radon test says whether the house is below the level you want.
What the manufacturer says
RadonAway's own statements, attributed
- RadonAway saysRadonAway states the 50036's extended 0 to 6.5 inch scale is for high-pressure radon fans whose recommended and maximum operating pressures go above 4 inches of water column.
- RadonAway saysRadonAway says the standard 0 to 4.5 inch Easy Read U-tube leaves little or no headroom for those fans.
- RadonAway saysRadonAway states its included 10-page OM&M and system information document meets current ANSI/AARST OM&M requirements.
- RadonAway saysRadonAway's catalog says its U-tube manometers let the homeowner know at a glance whether the radon system is operating.
- RadonAway saysRadonAway's catalog describes the U-tube packet as holding all labels and materials needed to comply with current standards.
These are RadonAway's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.
Independent evidence
Who checks a device like this
C-NRPP's consumer evaluation covers electronic radon monitors, not the parts of a mitigation system, so it has no result for RadonAway Easy Read U-Tube Manometer (50036). The standards and results the maker states are under “What the manufacturer says”, and what shows whether radon in your home is lower is a radon test after the work is done.
RadonAway Easy Read U-Tube Manometer (50036)
Check price on Amazon (opens in a new tab)Specifications
Specifications
Every figure as the maker states it
The maker's figures
- Type
- System indicator, U-tube manometer for a high-suction radon system, 0 to 6.5 in. WC
- What it reads
- Vacuum in the radon system's pipe, read from blue fluid in a U-tube against a 0 to 6.5 in. scale; does not measure radon
- Range
- 0 to 6.5 in. WC; for fans whose recommended and maximum operating pressures go above 4 in. WC (GX4, GX5, GX5A; optional for the EC6)
- Made of
- U-tube manometer with non-toxic fluid, adjustable zero and a molded scale curved to fit the system pipe (catalog features for RadonAway's U-tubes)
- Package
- Manometer with tubing and 2 self-tap screws, installation instructions, label package (4 pipe labels, fan circuit label in 2 sizes, system label, sump label), system information brochure and 10-page OM&M document, clear plastic bag with twist tie; 50 per case
- Warranty
- Not stated by the manufacturer
What is in the box
RadonAway's catalog lists the U-tube packet: the Easy Read U-tube manometer with tubing and 2 self-tap screws, installation instructions, a system and component label package (4 pipe labels, a fan circuit label in 2 sizes, a system label and a sump label), a system information brochure, and a clear plastic bag with a twist tie for hanging the information on the system. The trade page adds that the 10-page OM&M and system information document is included. The catalog lists the 50036 in blue, 50 to a case.
RadonAway's conditions of sale, printed on its trade page, say that goods it makes and sells are warranted to be free from defects in material and workmanship, and that it will repair or replace, without charge, any goods proven defective. The five-year warranty on the same page is about RadonAway's fans.
What it costs to run
A U-tube needs no power. Its upkeep is fluid and attention: RadonAway's gauge category sells a blue U-tube manometer gauge oil (P/N 20011) on its own, and Minnesota says both fan monitors should be checked monthly to make sure the mitigation system is working properly.
The fan behind the reading is the part that wears and the part that costs. RadonAway's catalog lists the GX4 at 74 to 158 watts and the GX5A at 80 to 180 watts, and the EPA says the fan should never be turned off and must run continuously for the system to work correctly, and that fans may last for five years or more.
The EPA also says it is a good idea to retest your home at least every two years to be sure radon levels remain low. The gauge cannot do that for you.
Fit and setup
Who it fits, and installation
The fit, then how it goes on and what the standards ask
Who it fits
Good fit if, and look elsewhere if
Good fit if
- Your system runs on a RadonAway GX4, GX5 or GX5A, the fans RadonAway names for this gauge.
- Your installer recorded a normal reading near or above 4 inches, too close to the top of a 0 to 4.5 inch tube.
- You are replacing a 6.5 inch Easy Read and want the same scale and mounting.
- You want the gauge to arrive with the system labels and information document RadonAway packs with it.
Look elsewhere if
- Your fan runs well below 4 inches; RadonAway's standard Easy Read, part 50017, reads 0 to 4.5 inches.
- Your system pulls beyond 6.5 inches, past the top of this scale; a gauge with a longer range fits.
- You want an alert when the fan stops; a U-tube has to be read, and Minnesota requires an active alarm as well.
- You want to know your radon level; the gauge reads suction, and only a radon test reads radon.
Installation
3 steps
- RadonAway supplies the gauge with its tubing and two self-tap screws for the pipe, and its catalog says the scale is molded and curved to fit the system pipe. Its catalog sets out the installer's last step: after a system is installed, affix the labels and manometer, and either give the documentation to the homeowner or put it in the clear plastic bag provided on an easily seen part of the system, usually on or near the manometer. The current standards, it says, require certain items to be located with a system in a readily observable indoor location.
- Minnesota's guidance explains why the starting reading matters: when a system is installed, the manometer reading is taken and written on a sticker next to the gauge, and fluid that is even, or significantly different from that reading, means the system may not be functioning properly. The EPA's 1994 standards ask the same of any manometer type gauge: it shall be clearly marked to indicate the range or zone of pressure readings that existed when the system was initially activated.
- High-suction fans are a mitigator's tool. The EPA recommends that you have a qualified radon mitigation contractor fix your home, and many states require radon professionals to be licensed, certified or registered. A post-mitigation radon test should be done within 30 days of installation, but no sooner than 24 hours after the system is running.
For how the sealing, the gauge and the fan work together, see radon mitigation systems, and to find someone to design and install one, radon mitigation professionals.
Compare
Compare with similar items
The same three rows for each, and the one difference that matters
Compared with similar products: 1 of 4
More radon manometers5
All radon manometersMore radon manometers: 1 of 5
Questions
Questions people ask
5 questions about the RadonAway Easy Read U-Tube Manometer (50036), answered
Asked about the Easy Read U-Tube Manometer (50036)
Which fans is the 6.5 inch gauge for?
RadonAway's trade page names its GX4, GX5 and GX5A, and makes it optional for the EC6 variable speed fan. Its 2023/2024 catalog says the gauge was introduced for the GX5A, which is capable of achieving 5 inches of vacuum.
Why not use the standard 4.5 inch Easy Read?
On a fan that pulls 4 inches or more, the fluid would sit at or past the top of the scale. RadonAway says its high-pressure fans leave little or no headroom on the standard gauge, and that the 4.5 inch gauge is not suitable for system pressures above 4.5 inches.
Does it measure radon?
No. RadonAway's catalog says its U-tube manometers do not measure radon levels; they measure vacuum pressure so you can see the system is operating. The EPA says it is a good idea to retest your home at least every two years.
What should the reading be?
The one recorded when your system was installed. Minnesota says that reading is written on a sticker next to the gauge, and the EPA's 1994 standards ask that the gauge be marked with the range of readings the system had when it was first activated.
The two sides are level. What now?
Minnesota says even fluid means the system may not be functioning properly. Its first checks are that the monitor tubing is connected to the pipe and not kinked, and that power is being supplied to the fan. Then call your installer; the EPA recommends a qualified radon mitigation contractor for repairs.
What to do next
- See how a radon system fits togetherThe suction point, the pipe, the fan, the gauge and the sealing, and what each one does.
- Find a mitigation professionalMost systems are designed and installed by one; some states require a license.
- Read a radon manometerWhat even or uneven fluid means, and what the gauge cannot tell you.
- Test after the workA short-term test afterwards shows whether radon in the home is lower.
Updated November 27, 2026