RadonAway
RadonAway GX4c
3 inch high suction radon fan, Contractor Series
- Radon fan
- 3.5 in. OD inlet and outlet
- 158 W
Best for, and skip if
Best for you if
- You are replacing a GX4c and want the figures RadonAway's IN167 instructions give for it.
- Your mitigator measured suction between 2.5 and 4.5 inches of water column, inside the 4.8 inch recommended maximum.
Skip it if
- The soil under the slab is open and the system needs volume more than suction; RadonAway lists no GX4c airflow below 2.5 inches.
- Measured suction runs past 4.8 inches; RadonAway's IN108 rates its GX5 to 5.2 inches.
Photos: RadonAway
As an Amazon Associate, Radon411 earns from qualifying purchases.
Amazon and the Amazon logo are trademarks of Amazon.com, Inc. or its affiliates.
See ratings and reviews on Amazon (opens in a new tab)- Pipe size3.5 in. OD inlet and outlet, 3.0 in. PVC Schedule 40 size compatible; recommended duct 3 or 4 in. Schedule 20/40 PVC, inline pipe mount with flex couplings (optional bracket available)
- Power draw158 W
- Every figure checked against the specifications RadonAway publishes
- The maker's own performance table, point by point, unranked
About this item
As RadonAway states it
- Pipe size: 3.5 in. OD inlet and outlet, 3.0 in. PVC Schedule 40 size compatible; recommended duct 3 or 4 in. Schedule 20/40 PVC, inline pipe mount with flex couplings (optional bracket available)
- Max power: 158 W
- Power supply: 120 V, 60 Hz AC, 1.5 A maximum for the RPc, GXc and XPc Series; 74 to 158 W
- Airflow at static pressure: 84 CFM at 2.50 in w.c.; 74 at 3.00; 63 at 3.50; 53 at 4.00; 41 at 4.50
- Outdoor use: Rated for outdoor installation
- Warranty: 12 months from purchase or 18 months from manufacture, whichever is sooner; extended to 60 months from purchase or 66 months from manufacture when installed by a professional radon mitigation contractor; no extension outside the Continental United States and Canada (IN167 Rev B)
The GX4c is the higher-suction member of RadonAway's GXc Series, the 3 inch fans in the same Contractor (C) line as its RPc and XPc models. RadonAway's IN167 instructions list it at 74 to 158 W with a maximum recommended operation pressure of 4.8 inches of water column at sea level, and give its airflow from 84 CFM at 2.5 inches down to 41 CFM at 4.5 inches. RadonAway publishes the same figures for its GX4 Pro Series fan, a separate model with its own instructions.
What you get
RadonAway does not publish a package list for the GX4c. IN167 mentions the wire nuts provided for the electrical connection and treats the mounting bracket and a vent muffler as optional. A system label, it says, is provided with the manometer rather than the fan. For the GX4 Pro, RadonAway's 2023/2024 catalog sells a GX4 Pro Pack, P/N 83021, with the fan, 3 by 3 inch couplings and a U-tube manometer; it lists no such pack for the GX4c.
In the box and running costsHow it works
What it does and how
The suction, the airflow and the housing, then who has checked it
How it works
In our words, from the maker's documents
Every active soil depressurization system has the same core: a vent fan that the EPA's guide describes drawing radon from below the home through suction pipes and releasing it outdoors, while holding a vacuum under the slab. The fan must stay on around the clock. What changes from house to house is how hard it has to pull, and the GX4c sits at the hard-pulling end of RadonAway's Contractor line.
IN167's table for the GXc Series runs from 1.5 to 4.5 inches of water column. For the GX4c it gives 84 CFM at 2.5 inches, 74 at 3.0, 63 at 3.5, 53 at 4.0 and 41 at 4.5, and leaves the lower pressures blank, so its airflow against light resistance is not stated by the maker. The smaller GX3c in the same table runs from 86 CFM at 1.5 inches to 40 CFM at 3.0, with a 3.3 inch recommended maximum.
The 4.8 inch maximum recommended operation pressure assumes sea level. IN167 tells the installer to take 4% off per 1,000 feet of altitude and another 10% for high temperature operation; at 3,000 feet that is 4.8 inches less 12%, or about 4.2 inches. If the system's vacuum exceeds the corrected figure, RadonAway's answer is more suction points.
IN167 gives the GX4c's power as 74 to 158 W on 120 V, 60 Hz AC, with the series rated 1.5 amps maximum, and its body as 10.9 inches high by 11.9 inches in diameter at 8 lbs 1 oz. The inlet and outlet are 3.5 inches in outside diameter, 3.0 inch PVC Schedule 40 size compatible, and the recommended duct is 3 or 4 inch Schedule 20/40 PVC with an inline pipe mount on flex couplings. The motor is continuous duty and thermally protected, with a 120°C (248°F) cutout and Class B insulation, and RadonAway rates the GXc fans for residential and commercial use.
How the GX4c differs from the GX4 Pro is mostly a matter of what RadonAway says about each. The GX4 Pro Series, part number 28585, has its own instructions (IN108) and product page, and its figures match the GX4c's: 74 to 158 W, 4.8 inches, and 84 down to 41 CFM from 2.5 to 4.5 inches. IN108 rates the GX Pro fans at 1.8 amps maximum against IN167's 1.5 for the C Series, and RadonAway's Pro page lists an Eternalast polycarbonate housing, Vapor Tite technology and a built-in water bypass, none of which IN167 mentions for the GXc fans; IN167 says only that they are factory sealed. RadonAway publishes no side-by-side of the two.
The GX4 Pro also appears in RadonAway's 2023/2024 catalog, which adds one more point for it, 14 CFM at 5.0 inches, and describes the GX fans as capable of operating at up to 5 inches of vacuum and chosen for moderate to tight soils. The catalog has no GXc fans at all; for the GX4c, IN167 is the document.
What the manufacturer says
RadonAway's own statements, attributed
- RadonAway saysRadonAway lists the GX4c at 74 to 158 W with a maximum recommended operation pressure of 4.8 in. WC at sea level and 84, 74, 63, 53 and 41 CFM at 2.5 to 4.5 in. WC.
- RadonAway saysRadonAway states the RPc, GXc and XPc Series fans are factory sealed, with no additional caulk needed to inhibit air leakage.
- RadonAway saysRadonAway states the GXc fans are rated for residential and commercial use and for indoor or outdoor installation.
- RadonAway saysRadonAway describes its GX4 Pro, the Pro Series fan with the same published figures, as optimal for moderate to tight soils and rated for commercial or residential use.
- RadonAway saysRadonAway states it extends the GXc fans' warranty to 60 months from purchase when a professional radon mitigation contractor installs the fan.
These are RadonAway's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.
Independent evidence
Who checks a device like this
C-NRPP's consumer evaluation covers electronic radon monitors, not mitigation fans, so it has no result for RadonAway GX4c. The safety listing and performance certification the maker states are under “What the manufacturer says”, and what shows whether any fan is working in your home is a radon test after it is installed.
RadonAway GX4c
Check price on Amazon (opens in a new tab)Specifications
Specifications
Every figure as the maker states it
The maker's figures
- Type
- Mitigation fan, inline
- Motor
- Not stated by the manufacturer
- Pipe size
- 3.5 in. OD inlet and outlet, 3.0 in. PVC Schedule 40 size compatible; recommended duct 3 or 4 in. Schedule 20/40 PVC, inline pipe mount with flex couplings (optional bracket available)
- Max static pressure
- Not stated by the manufacturer
- Max airflow
- Not stated by the manufacturer
- Max power
- 158 W
- Power supply
- 120 V, 60 Hz AC, 1.5 A maximum for the RPc, GXc and XPc Series; 74 to 158 W
- Speed control
- Not stated by the manufacturer
- Airflow at static pressure
- 84 CFM at 2.50 in w.c.; 74 at 3.00; 63 at 3.50; 53 at 4.00; 41 at 4.50
- Outdoor use
- Rated for outdoor installation
- Warranty
- 12 months from purchase or 18 months from manufacture, whichever is sooner; extended to 60 months from purchase or 66 months from manufacture when installed by a professional radon mitigation contractor; no extension outside the Continental United States and Canada (IN167 Rev B)
What is in the box
RadonAway does not publish a package list for the GX4c. IN167 mentions the wire nuts provided for the electrical connection and treats the mounting bracket and a vent muffler as optional. A system label, it says, is provided with the manometer rather than the fan. For the GX4 Pro, RadonAway's 2023/2024 catalog sells a GX4 Pro Pack, P/N 83021, with the fan, 3 by 3 inch couplings and a U-tube manometer; it lists no such pack for the GX4c.
IN167's warranty runs 12 months from purchase or 18 months from manufacture, whichever is sooner, and RadonAway extends it to 60 months from purchase or 66 months from manufacture when a professional radon mitigation contractor installs the fan. Outside the continental United States and Canada only the standard term applies. Proof of purchase, and of professional installation, may be required; a return needs a Return Material Authorization number and travels at the owner's cost.
What it costs to run
The fan runs every hour of the year, so electricity is the cost to plan for. At IN167's top figure of 158 W, continuous running uses about 1,384 kWh a year; at 74 W, about 648 kWh. The suction your system holds sets where in that range it runs, and your utility rate sets the bill.
IN167's annual checks are short: connections tight and leak-free, fan and ducting secure and vibration-free, vacuum on the manometer inside its normal range and under the corrected maximum, and radon levels tested to EPA protocol. The EPA's guide says fans may last five years or more, that manufacturer warranties tend not to exceed five years, and that a home should be retested at least every two years.
Airflow at each pressure
RadonAway's performance table, point by point
| Static pressure | Airflow |
|---|---|
| 2.50 in w.c. | 84 CFM |
| 3.00 in w.c. | 74 CFM |
| 3.50 in w.c. | 63 CFM |
| 4.00 in w.c. | 53 CFM |
| 4.50 in w.c. | 41 CFM |
Airflow falls as the suction the system needs rises. A mitigator matches the fan to pressure measured under the slab.
Fit and setup
Who it fits, and installation
The fit, then how a system goes in
Who it fits
Good fit if, and look elsewhere if
Good fit if
- You are replacing a GX4c and want the figures RadonAway's IN167 instructions give for it.
- Your mitigator measured suction between 2.5 and 4.5 inches of water column, inside the 4.8 inch recommended maximum.
- The system is plumbed in 3 inch PVC, which the GX4c's 3.5 inch outside-diameter inlet and outlet are sized for.
- You want a fan RadonAway rates for both homes and commercial buildings.
Look elsewhere if
- The soil under the slab is open and the system needs volume more than suction; RadonAway lists no GX4c airflow below 2.5 inches.
- Measured suction runs past 4.8 inches; RadonAway's IN108 rates its GX5 to 5.2 inches.
- You want the Vapor Tite sealing and Eternalast housing RadonAway lists for the GX4 Pro, which its IN167 does not claim for the GX4c.
- You are planning a first system yourself; the EPA recommends a qualified radon mitigation contractor.
Installation
6 steps
- The EPA recommends a qualified radon mitigation contractor for fixing a home, and many states require radon professionals to be licensed, certified or registered. IN167 says the RPc, GXc and XPc fans are intended for use by trained, professional, certified or licensed radon mitigators, and RadonAway's retail page adds that non-professional installation is not intended to take the place of a qualified radon professional.
- IN167 has the GX4c mounted vertically with the outlet up, plumb and level, either directly on the system piping or fastened to a structure with RadonAway's optional mounting bracket, and kept off building surfaces so vibration does not carry. Flexible couplings finish the piping run and act as the disconnect for servicing. The fan can go indoors or outdoors but is not suitable for underground burial.
- Ducting matters more than it looks. IN167 says the run from the fan to the outside strongly affects noise and fan energy use, asks for the shortest, straightest route and warns against ducts smaller than recommended. Where freezing and moisture are both present, it recommends a condensate bypass for added protection, and its pitch table asks for a rise of 1/4 inch per foot at 25 CFM and 3/8 inch at 50 CFM in 3 inch pipe.
- Wiring is a job for a qualified and licensed electrician, to the National Electrical Code and local codes, by IN167's account. Outdoor installations need a UL Listed watertight conduit; exterior boxes should be outdoor rated, sealed and drained by a weep hole; and the fan is not intended for rigid metal conduit. Some RadonAway fans use two-wire motors, and IN167 says the supply's ground is then capped inside the fan's electrical box.
- The EPA's construction guide says the fan and every positively pressurized part of the vent pipe belong outside habitable space, so a leak at the housing or a joint cannot pump radon into the home, and that the fan goes in a vertical run of the vent pipe.
- IN167 makes a system monitor, a manometer or an audible alarm, a requirement, along with a label telling occupants how to reach the installer and to keep testing. The EPA's guide says the warning device must be placed where it can be seen or heard easily, and that a post-mitigation radon test should be done within 30 days of installation, but no sooner than 24 hours after the fan is running.
To find someone to design and install a system, see radon mitigation professionals, and for how a fan fits into one, how a radon fan works.
Compare
Compare with similar items
The same three rows for each, and the one difference that matters
Compared with similar products: 1 of 4
More radon fan models6
All radon fan modelsMore radon fan models: 1 of 6
Questions
Questions people ask
6 questions about the RadonAway GX4c, answered
Asked about the GX4c
Is the GX4c the same fan as the GX4 Pro?
RadonAway treats them as two models. The GX4 Pro is part number 28585, with its own IN108 instructions, and its product page lists Vapor Tite sealing, an Eternalast housing and a built-in water bypass. The GX4c is covered by IN167 with the C Series fans. The performance figures RadonAway prints for the two are the same.
How much air does the GX4c move?
IN167 lists 84 CFM at 2.5 inches of water column, 74 at 3.0, 63 at 3.5, 53 at 4.0 and 41 at 4.5. RadonAway gives no figure for it at lower suction.
What is the highest suction it should run at?
4.8 inches of water column at sea level, by IN167, reduced by 4% per 1,000 feet of altitude and by a further 10% for high temperature operation. A reading above that calls for more suction points.
Can the GX4c be mounted outside?
Yes, by RadonAway's account: IN167 rates the GXc fans for indoor or outdoor use and calls for a UL Listed watertight conduit on outdoor wiring. The EPA's construction guide adds that the fan belongs outside the home's living space either way.
What warranty does the GX4c have?
IN167 gives 12 months from purchase or 18 months from manufacture, extended to five years from purchase when a professional radon mitigation contractor installs it, within the continental United States and Canada.
Can a homeowner install it?
The EPA recommends a qualified radon mitigation contractor, and many states require radon professionals to be licensed, certified or registered. RadonAway writes IN167 for trained, certified or licensed mitigators, wants the wiring done by a licensed electrician, and only extends the warranty for professional installation.
What to do next
- See every radon fan we coverEach maker's published pressure, airflow and power, side by side.
- Find a mitigation professionalMost systems are designed and installed by one; some states require a license.
- Understand the fanWhat the fan does in a system, and when one needs replacing.
- Test after it runsA short-term test after installation shows whether the system works.
Updated November 27, 2026