Skip to content

RadonAway

RadonAway GX5

3 inch high suction radon fan

  • Radon fan
  • 3.5 in. OD inlet and outlet
  • 180 W

Best for, and skip if

Best for you if

  • A mitigator has measured tight sub-slab soil and the system needs suction in the 4 to 5 inch range, under RadonAway's 5.2 inch ceiling.
  • You are replacing a GX5 whose label reads part number 28586 and want RadonAway's figures for that fan.

Skip it if

  • The slab sits on open gravel or drain tile; RadonAway aims the GX5 at moderate to tight soils and prints no airflow below 2.5 inches.
  • You want a smaller power draw; RadonAway lists the GX5 at up to 180 W, against 158 W for the GX4c.
  • RadonAway GX5

Photos: RadonAway

  • Pipe size3.5 in. OD inlet and outlet, 3.0 in. PVC Schedule 40 size compatible; recommended ducting 3 or 4 in. PVC pipe, inline pipe mount with flex couplings (optional bracket available); airflow to be kept below 90 CFM in 3 in. pipe for drainage (IN108)
  • Power draw180 W
  • Every figure checked against the specifications RadonAway publishes
  • The maker's own performance table, point by point, unranked
Tests that check it works

About this item

As RadonAway states it

  • Pipe size: 3.5 in. OD inlet and outlet, 3.0 in. PVC Schedule 40 size compatible; recommended ducting 3 or 4 in. PVC pipe, inline pipe mount with flex couplings (optional bracket available); airflow to be kept below 90 CFM in 3 in. pipe for drainage (IN108)
  • Max power: 180 W
  • Power supply: 120 V, 60 Hz AC, 1.8 A maximum for the GX Pro Series; 75 to 180 W
  • Airflow at static pressure: 98 CFM at 2.50 in w.c.; 93 at 3.00; 76 at 3.50; 65 at 4.00; 54 at 4.50; 31 at 5.00
  • Outdoor use: Rated for outdoor installation
  • Warranty: 12 months from purchase or 18 months from manufacture, whichever is sooner; extended to 60 months from purchase or 66 months from manufacture when installed by a professional radon mitigation contractor; no extension outside the Continental United States and Canada (IN108 Rev F); the product page lists a 5-year limited warranty

The GX5 is the strongest of the three fans in RadonAway's GX Pro Series, part number 28586, built for a 3 inch pipe. RadonAway gives it a maximum recommended operating pressure of 5.2 inches of water column at sea level and a draw of 75 to 180 W, and its instructions list 98 CFM at 2.5 inches tapering to 31 CFM at 5.0 inches: a fan meant for suction against tight soil rather than volume through open gravel.

What you get

RadonAway does not publish a package list for the GX5. IN108 mentions the wire nuts provided for the electrical connection, and treats the mounting bracket (P/N 25007), a vent muffler (P/N 24003 or 24007), a manometer and any alarm as items available separately. Its mounting section calls for flexible couplings to join the fan to the pipe without saying they come with it.

In the box and running costs

How it works

What it does and how

The suction, the airflow and the housing, then who has checked it

How it works

In our words, from the maker's documents

Clay, silt and compacted fill let little air pass, so a system over that kind of ground has to pull hard to spread its low pressure under the whole slab. The EPA's construction guide puts the goal plainly: the vent fan has to keep the pressure beneath the slab or membrane lower than the pressure above it. On tight ground that is a job for suction, and RadonAway describes the GX5 as optimal for moderate to tight soils.

RadonAway's IN108 instructions (Rev F, July 2025) start the GX5's airflow table at 2.5 inches of water column: 98 CFM at 2.5 inches, 93 at 3.0, 76 at 3.5, 65 at 4.0, 54 at 4.5 and 31 at 5.0. Nothing is printed for lower pressures, so the GX5's airflow against little resistance is not stated by the maker. The product page puts the top of the range in one line: engineered to move over 30 CFM at 5.0 inches of WC, measured at sea level.

The 5.2 inch figure is a ceiling, and it shrinks with height and heat. IN108 calls it the maximum recommended operation pressure for sea level operation, to be cut by 4% per 1,000 feet of altitude and by a further 10% in high temperature environments. Worked through for a house at 5,000 feet, that is 5.2 inches less 20%, or about 4.2 inches. When a system's vacuum reading runs above the ceiling, RadonAway's instruction is to add suction points.

IN108 rates the GX5 at 75 to 180 W on 120 V, 60 Hz AC, with the GX Pro Series drawing 1.8 amps at most. It weighs 8 lbs 15 oz, the heaviest of the series (the GX3 is 7 lbs 10 oz and the GX4 8 lbs 1 oz), and the series shares one body size, 10.9 inches high by 11.9 inches across, with a 3.5 inch outside-diameter inlet and outlet that is 3.0 inch PVC Schedule 40 size compatible. The motor runs continuous duty at 3000 RPM, thermally protected, with a 120°C (248°F) thermal cutout and Class B insulation.

On the housing and sealing, RadonAway's product page lists an Eternalast polycarbonate plastic housing, Vapor Tite technology to inhibit radon and soil gas leakage, a water-hardened thermally protected motor and a built-in water bypass, and says the fan is ETL listed by Intertek and UL507 compliant. IN108 adds that the GX Pro Series fan is factory sealed, so no caulk or other material is needed to stop air leaking from it.

One name to keep apart from it: the GX5A. RadonAway's 2023/2024 catalog lists the GX3, the GX4 and the GX5A, part number 28536, a 4 inch fan at 80 to 180 W with a 5.0 inch recommended maximum and 178 CFM at 0 inches, and notes that the GX5A is sealed to inhibit radon leakage but does not use Vapor Tite sealing technology. The GX5, part number 28586, does not appear in that catalog, so every GX5 figure on this page comes from IN108 and the product page.

What the manufacturer says

RadonAway's own statements, attributed

  • RadonAway saysRadonAway lists a maximum operating pressure of 5.2 inches of WC for the GX5 Pro Series (SKU 28586) and says it moves over 30 CFM at 5.0 inches of WC, both measured at sea level.
  • RadonAway saysRadonAway states the GX5 is optimal for moderate to tight soils and rated for indoor and outdoor use, commercial or residential.
  • RadonAway saysRadonAway describes Vapor Tite technology to inhibit radon and soil gas leakage and an Eternalast polycarbonate plastic housing on the GX5.
  • RadonAway saysRadonAway states the GX Pro Series fan is factory sealed and designed to perform year-round in all but the harshest climates.
  • RadonAway saysRadonAway's product page lists a 5-year limited warranty and says the GX5 is made in the USA with U.S. and imported parts.

These are RadonAway's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.

Independent evidence

Who checks a device like this

C-NRPP's consumer evaluation covers electronic radon monitors, not mitigation fans, so it has no result for RadonAway GX5. The safety listing and performance certification the maker states are under “What the manufacturer says”, and what shows whether any fan is working in your home is a radon test after it is installed.

Specifications

Specifications

Every figure as the maker states it

Compare side by side

The maker's figures

Type
Mitigation fan, inline
Motor
Not stated by the manufacturer
Pipe size
3.5 in. OD inlet and outlet, 3.0 in. PVC Schedule 40 size compatible; recommended ducting 3 or 4 in. PVC pipe, inline pipe mount with flex couplings (optional bracket available); airflow to be kept below 90 CFM in 3 in. pipe for drainage (IN108)
Max static pressure
Not stated by the manufacturer
Max airflow
Not stated by the manufacturer
Max power
180 W
Power supply
120 V, 60 Hz AC, 1.8 A maximum for the GX Pro Series; 75 to 180 W
Speed control
Not stated by the manufacturer
Airflow at static pressure
98 CFM at 2.50 in w.c.; 93 at 3.00; 76 at 3.50; 65 at 4.00; 54 at 4.50; 31 at 5.00
Outdoor use
Rated for outdoor installation
Warranty
12 months from purchase or 18 months from manufacture, whichever is sooner; extended to 60 months from purchase or 66 months from manufacture when installed by a professional radon mitigation contractor; no extension outside the Continental United States and Canada (IN108 Rev F); the product page lists a 5-year limited warranty

What is in the box

RadonAway does not publish a package list for the GX5. IN108 mentions the wire nuts provided for the electrical connection, and treats the mounting bracket (P/N 25007), a vent muffler (P/N 24003 or 24007), a manometer and any alarm as items available separately. Its mounting section calls for flexible couplings to join the fan to the pipe without saying they come with it.

RadonAway states the warranty twice. The product page lists a 5-year limited warranty. IN108 gives the terms: 12 months from purchase or 18 months from manufacture, whichever is sooner, extended to 60 months from purchase or 66 months from manufacture when a professional radon mitigation contractor installs the fan, with no extension outside the continental United States and Canada. A claim needs a Return Material Authorization number, and the fan travels to the factory at the owner's cost.

What it costs to run

Power is the running cost, and the GX5 never switches off. At RadonAway's top figure of 180 W, a year of continuous running comes to about 1,577 kWh; at the 75 W bottom of the range, about 657 kWh. Where a given system lands depends on the suction it works against, and your utility rate turns that into a bill. The EPA notes that systems with fans slightly increase the electric bill.

There is nothing to refill or replace on a schedule. IN108's yearly checklist is to confirm the connections are tight and leak-free, the fan and ducting are secure and vibration-free, the manometer sits in its normal range and under the recommended maximum, and radon levels are tested to current industry standards. The EPA's guide expects fans to last five years or more, notes that manufacturer warranties tend not to exceed five years, and suggests retesting the home at least every two years.

Airflow at each pressure

RadonAway's performance table, point by point

Static pressureAirflow
2.50 in w.c.
98 CFM
3.00 in w.c.
93 CFM
3.50 in w.c.
76 CFM
4.00 in w.c.
65 CFM
4.50 in w.c.
54 CFM
5.00 in w.c.
31 CFM

Airflow falls as the suction the system needs rises. A mitigator matches the fan to pressure measured under the slab.

Fit and setup

Who it fits, and installation

The fit, then how a system goes in

Who it fits

Good fit if, and look elsewhere if

Good fit if

  • A mitigator has measured tight sub-slab soil and the system needs suction in the 4 to 5 inch range, under RadonAway's 5.2 inch ceiling.
  • You are replacing a GX5 whose label reads part number 28586 and want RadonAway's figures for that fan.
  • The riser is 3 inch PVC, the size the GX5's 3.5 inch outside-diameter inlet and outlet are made to fit.
  • The fan will sit outdoors or in an attic, which RadonAway allows with a watertight conduit for outdoor wiring.

Look elsewhere if

  • The slab sits on open gravel or drain tile; RadonAway aims the GX5 at moderate to tight soils and prints no airflow below 2.5 inches.
  • You want a smaller power draw; RadonAway lists the GX5 at up to 180 W, against 158 W for the GX4c.
  • You meant the 4 inch GX5A, a different RadonAway fan under part number 28536.
  • You are designing a first system yourself; the EPA recommends a qualified mitigation contractor, and RadonAway writes its GX instructions for trained mitigators.

Installation

6 steps

  1. The EPA recommends that a qualified radon mitigation contractor fix a home, and notes that many states require radon professionals to be licensed, certified or registered. RadonAway's IN108 says the GX Pro Series fan is intended for use by trained, professional, certified or licensed radon mitigators, and that industry standards and federal, state, county and local codes take precedence over its instructions where they conflict.
  2. IN108 asks for the fan to hang vertically with the outlet up, plumb and level, joined to the pipe with flexible couplings that serve as the service disconnect and as vibration isolation, and clear of any building surface. RadonAway's optional mounting bracket, P/N 25007, can carry it instead. Water must never be able to pool inside the housing, and the fan is not suitable for underground burial.
  3. Condensate sets the slope of the pipe. IN108 says the system must let water drain back to a slab hole, and that for proper drainage airflow should be kept below 90 CFM in 3 inch pipe. Its own table shows the GX5 at 98 CFM at 2.5 inches and 93 CFM at 3.0 inches, so on 3 inch pipe that limit matters at the low-suction end of the fan's range. The pitch table asks for a rise of 1/4 inch per foot at 25 CFM and 3/8 inch at 50 CFM in 3 inch pipe.
  4. IN108 says all wiring must be done by a qualified and licensed electrician to the National Electrical Code and local codes, that outdoor installations need a UL Listed watertight conduit, and that exterior boxes should be outdoor rated and sealed, with a weep hole to drain them. The fan is not meant for rigid metal conduit, should not sit on the piping unpowered for more than 48 hours, and every fuel-burning appliance should be checked for backdrafting once it runs.
  5. On location, the EPA's construction guide says the fan goes in a vertical run of the vent pipe, outside habitable space, and names attics and garages without living space above as the usual places. It rules out the living space and the crawlspace beneath the home, and says a fan needs an unswitched electrical junction box.
  6. The EPA's guide says a warning device must be installed to alert you if an active system stops working properly, usually a manometer. IN108 names a 6.5 inch U-tube manometer, such as P/N 50036, as compatible with the GX5, where the GX3 can also use a 4.5 inch gauge, and lists audible alarms (P/N 28001-2, 28001-4, 28421 or 28535) as an option. A post-mitigation radon test should follow within 30 days of installation, but no sooner than 24 hours after the fan starts.

To find someone to design and install a system, see radon mitigation professionals, and for how a fan fits into one, how a radon fan works.

Compare

Compare with similar items

The same three rows for each, and the one difference that matters

Compare side by side
  • This page

    RadonAway GX5

    What it does
    Not stated
    Power
    Up to 180 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    This page: The GX5 is the strongest of the three fans in RadonAway's GX Pro Series, part number 28586, built for a 3 inch pipe.

  • What it does
    Moves up to 241 CFM
    Power
    Up to 310 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: Another maker's 3 inch fan: Festa's 2022 catalog gives the AMG Eagle 241 CFM maximum flow and 4.2 inches maximum pressure, and its replacement guide names it for an installed GX4 or GX5.

  • What it does
    Not stated
    Power
    Up to 146 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: RadonAway's older 3 inch high-suction design: its Contractor Series table lists the GP501c at 68 to 146 W with a 3.8 inch recommended maximum.

  • What it does
    Not stated
    Power
    Up to 158 W
    C-NRPP 2024/25
    Not applicable (mitigation fan)

    The difference: The GX fan one step down, in RadonAway's Contractor Series: IN167 lists the GX4c at 74 to 158 W with a 4.8 inch recommended maximum and 84 CFM at 2.5 inches.

More radon fan models6

All radon fan models

Questions

Questions people ask

6 questions about the RadonAway GX5, answered

Asked about the GX5

Is the GX5 the same fan as the GX5A?

No. The GX5A in RadonAway's 2023/2024 catalog is part number 28536, a 4 inch fan with a 5.0 inch recommended maximum that does not use Vapor Tite sealing. The GX5 is part number 28586, a 3 inch fan that IN108 rates to 5.2 inches. Check the part number on the label before ordering a replacement.

How much air does the GX5 move?

RadonAway publishes it only under real suction: 98 CFM at 2.5 inches of water column, 76 at 3.5 and 31 at 5.0, from IN108, and over 30 CFM at 5.0 inches on the product page. It gives no figure below 2.5 inches.

Which manometer suits a GX5?

IN108 lists the GX3, GX4 and GX5 as compatible with a 6.5 inch U-tube manometer, such as RadonAway P/N 50036, and says a system label comes with that gauge. It names the 4.5 inch gauge (P/N 50017) for the GX3 only.

What pipe does the GX5 take?

IN108 gives a 3.5 inch outside-diameter inlet and outlet, 3.0 inch PVC Schedule 40 size compatible, and lists 3 or 4 inch PVC as the recommended ducting for the GX fans. It also asks that airflow stay below 90 CFM in 3 inch pipe so condensate can drain.

What warranty comes with the GX5?

RadonAway's product page lists a 5-year limited warranty. IN108 makes the five years depend on a professional radon mitigation contractor doing the installation; otherwise the term is 12 months from purchase or 18 months from manufacture, whichever comes first.

Do I need a professional to install it?

The EPA recommends a qualified radon mitigation contractor, and many states license, certify or register radon professionals. RadonAway writes its GX instructions for trained, certified or licensed mitigators, requires a licensed electrician for the wiring, and ties its longer warranty to professional installation.

Updated November 27, 2026