MonitorAEGTEST
HOUND-1011 rechargeable radon detector with a screen
- C-NRPP 2024/25: Not included
- Battery
- Alarm
- Screen
Method: Semiconductor sensor
First reading: Within 6 hours
AEGTEST
Palm-sized rechargeable radon detector
Photos: AEGTEST
As an Amazon Associate, Radon411 earns from qualifying purchases.
Amazon and the Amazon logo are trademarks of Amazon.com, Inc. or its affiliates.
See ratings and reviews on Amazon (opens in a new tab)As AEGTEST states it
The HOUND-1085 is a palm-sized, rechargeable radon detector from AEGTEST: a semiconductor sensor behind a triple-vent design, a first reading after 6 hours and hourly updates after that, color-coded bars with sound alerts, and up to 504 days of history on the device. AEGTEST's earlier store listed a range of 0.09 to 1500 pCi/L and an accuracy of ±15%; AEGTEST posts no manual online, and the HOUND-1085 was not included in C-NRPP's 2024/25 consumer monitor evaluation.
AEGTEST lists one HOUND-1085 radon detector, a charging data cable and a user manual, ready to use out of the box. The manual is in the box only: AEGTEST posts no copy online, and the general help page of its earlier store answered the question of where to find the instruction guide by asking buyers to contact the company. AEGTEST sells the HOUND-1085 under two listings on its own store, one of them in grey.
In the box and running costsHow it works
The sensor, the sampling and the readings, then who has checked it
In our words, from the maker's documents
AEGTEST says the HOUND-1085 integrates a high-accuracy semiconductor radon sensor with a triple-vent design to accelerate radon diffusion: air reaches the sensor on its own through the vents, and AEGTEST names no pump. The FAQ on its earlier store's HOUND-1085 page gave AEGTEST's account of how its detectors measure: the sensor counts the alpha particles of radon in each sample of air it analyzes, works continuously, and every hour produces a data point that contributes to an average reading, which is why the readings show as averages over 24, 48 and 96 hours.
The first reading appears after 6 hours, AEGTEST says, and then updates automatically every hour. The device logs a value every 6 hours and keeps a history of up to 504 days, with short-term views of the past 6, 24, 48 and 96 hours, all shown on the device itself. AEGTEST's description mentions no app, Wi-Fi or Bluetooth.
AEGTEST's current product page gives no measurement range or accuracy. The specification table on its earlier online store listed a reaction range of 0.09 to 1500 pCi/L, an accuracy of ±15%, a first display after the device has worked for 6 hours, and operating conditions of 14° to 113°F, with the humidity value missing from the row. The table gives no radon level or test period for the ±15%, and no AEGTEST page says whether the HOUND-1085 can show Bq/m³, so that option is not stated by the maker.
Power is a rechargeable battery: AEGTEST says it recharges in 3.5 hours and gives over 1 month of continuous monitoring. The earlier store's table listed it as a 2500mAh, 3.7 V lithium battery, beside a weight of 0.27 lbs, and the earlier store put its runtime at up to 45 days in ECO mode. Neither store names the charging port.
For warnings, AEGTEST describes color-coded bars that indicate radon levels, paired with customizable sound alerts that warn of elevated concentrations. It does not say what level sets the sound off, or whether customizable means the level, the volume or both, so the alarm level is not stated by the maker.
AEGTEST's own statements, attributed
These are AEGTEST's own statements, attributed to it. They are not our findings, and we have not tested this product ourselves.
C-NRPP 2024/25, recalls and studies
The Canadian National Radon Proficiency Program's 2024/25 comparison of consumer monitors did not include AEGTEST HOUND-1085. That is a fact about which devices took part, not a finding about this one: no result from that program exists for it either way.
C-NRPP is the Canadian National Radon Proficiency Program. Its 2024/25 results were published in May 2025.
Specifications
Every figure as the maker states it
AEGTEST lists one HOUND-1085 radon detector, a charging data cable and a user manual, ready to use out of the box. The manual is in the box only: AEGTEST posts no copy online, and the general help page of its earlier store answered the question of where to find the instruction guide by asking buyers to contact the company. AEGTEST sells the HOUND-1085 under two listings on its own store, one of them in grey.
AEGTEST's warranty page, which covers its store as a whole, promises a three-year warranty, described as a 36-month after-sales service with lifetime technical support. It excludes faults caused by unauthorized disassembly, damage from water or strong mechanical force, and normal wear that does not affect function, says AEGTEST is not responsible for loss of use or incidental damages, and points buyers to AEGTEST's support email for warranty help or repair.
There is no lab fee and no battery to buy: the 2500mAh lithium battery the earlier store listed is recharged with the cable in the box, in 3.5 hours by AEGTEST's figure. AEGTEST mentions no app, subscription or cloud service for the HOUND-1085, and it publishes no sensor life, recalibration interval or service schedule.
Fit and setup
The fit, then setup and placement as the guidance asks
Good fit if, and look elsewhere if
Good fit if
Look elsewhere if
4 steps
How C-NRPP says to use any consumer monitor
For where any radon test or monitor should sit in a home, see where to place a radon test.
Compare
The same three rows for each, and the one difference that matters
Compared with similar products: 1 of 4
More home radon monitors: 1 of 31
Questions
6 questions about the AEGTEST HOUND-1085, answered
AEGTEST, which sells it on its own online store. The store's own record gives Shenzhen, Guangdong, China as its location and prices in US dollars, and lists the United States among the countries it ships to. The AEGTEST trademark is registered in the US to Shenzhen Xunyi Electronic Commerce Co., Ltd., with radon detectors among the goods it covers.
AEGTEST's earlier store listed ±15% in its specification table, with no radon level or test period attached; its current page calls the sensor high-accuracy without a figure.
There is no independent result to compare it with: the HOUND-1085 was not included in C-NRPP's 2024/25 consumer monitor evaluation. That is not a failed test; it means no independent result exists.
The FAQ on AEGTEST's earlier store page for the HOUND-1085 says the device is exposed to radon during final factory testing, so first readings may be high. Its fix is to blow air across the inlet with a fan for a few minutes to clear the residual radon, then restart the measurement. AEGTEST's current store does not raise the point.
The FAQ on AEGTEST's earlier store page for the HOUND-1085 says that after a restart or the Retest function, the measurement screen resets while the history is kept, and to wait 6 hours for the first reading to appear.
The FAQ on AEGTEST's earlier store page for the HOUND-1085 says both can. It advised keeping humidity below 90% and keeping the detector out of strong light such as sunlight or a camera flash; if it has been exposed, put it somewhere dark, such as a drawer, and wait before measuring again. AEGTEST's current store does not mention humidity or light for the HOUND-1085.
The FAQ on AEGTEST's earlier store page for the HOUND-1085 recommended at least 3 to 7 days, and said that after one month a detector has probably gathered enough data to start showing a pattern, with the average settling on a reference level. For a decision about fixing a home, C-NRPP's advice for any consumer monitor is a minimum of 3 months, preferably in the heating season.
Updated October 9, 2026